Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/WWM
Permit Number - T12CM08194
Review Name: RESIDENTIAL - BLDG/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/29/2013 | CLAYTON TREVILLYAN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | PLAN REVIEW COMMENTS Date: 1-30-13 Activity: T12CM08194 Address: 2428 E Menor Sv Applicant: Raul Sereno Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, along with a written response to each of the noted items indicating action taken. SCOPE OF REVIEW: The scope of this plan review includes architectural, electrical, plumbing, mechanical, and energy conservation. The purpose of this review is to verify compliance to the 2006 International Residential Code with local amendments. Other comment references may be derived from additional codes and standards adopted by The City of Tucson. All features have been checked only to the extent allowed by the submittals provided for review. All portions of this project are assumed to meet other departmental requirements, conditions, and concerns before permit approval. ELEVATIONS: 1. Specify height above grade for finished floor, windows/doors, exterior walls, rooflines, porches, chimneys, etc. PLUMBING PLAN: 2. Specify the total developed length from the gas meter to the most remote appliance on the system, G2413.1, Table G2413.4 (1). 3. Two-way cleanout required on grey water building drain within 2' from the building. MECHANICAL PLAN: 4. Provide Manual J/S/D calculations for the forced air unit in accordance with M1401.3, M1601.1. 5. Show supply and return air ducts with a minimum R-8 insulation when located outside the thermal envelope, R1103.2.1. 6. Show exhaust fan capacities for bathroom and kitchen venting to the exterior (min 50 and 100 CFM rating respectively), R303.3, M1507. OUTDOOR LIGHTING CODE 7. Include lumen calculation for partial acre lots (55,000*0.24=13,200 max lumens and 12,000*0.24=2,880 max unshielded lumens) If you have any questions please contact: Clayton Trevillyan 520.837.4913 Residential Plan Review |
| 02/04/2013 | ERICA SANCHEZ | WWM | REVIEW | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 02/05/2013 | CPIERCE1 | REJECT SHELF | Completed |