Permit Number: T12CM08171
Parcel: 117132170

Review Status: Completed

Review Details: COMMERCIAL - TI

Permit Number - T12CM08171
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/11/2013 CPIERCE1 WWM REVIEW Needs Review
12/27/2012 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Approved
12/27/2012 ERIC NEWCOMB ADA REVIEW Passed
12/27/2012 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change 1. Clarify the plumbing code to be used for this activity. The plumbing specifications on sheet p1.2 refer to the 2006 UPC but the project data section on sheet a1.0 refers to the 2006 IPC. This review has been made using the 2006 UPC.
2. Verify that the installation of the water heater, expansion tank, and the recirculating pump comply with the manufacturers' specifications for clearances. Reference: Section 310.4, UPC 2006.
3. Show the route and termination of the T&P relief and the pan drain.
4. Provide material standards for all plumbing fixtures being provided by others. Reference: Section 401.1, UPC 2006.
12/27/2012 ROBERT SHERRY WATER REVIEW Approved
12/27/2012 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Approved
12/31/2012 LHANLY1 FIRE REVIEW Approved separate permits required for any required sprinkler changes and for alarms.
12/31/2012 LEERAY HANLY ELECTRICAL-COMMERCIAL REVIEW Approved