Permit Number: T12CM08170
Parcel: 118051830

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING-WALKTHRU

Permit Number - T12CM08170
Review Name: RESIDENTIAL - BLDG/ZONING-WALKTHRU
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/29/2013 TERRY STEVENS ZONING REVIEW Denied CDRC TRANSMITTAL

FROM: Michael St.Paul: Planning Technician


PROJECT:
T12CM08170
1602 South Via Elnora
Detached carport for SFR


TRANSMITTAL: December 27, 2012

COMMENTS: The following comments are for the purpose of applying for a variance before the Board of Adjustment.


The site is in the R-1 Zone (LUC Section 2.3.4.2.A.1.). The Development Designator is "G" (LUC Section 3.2.3.1.B). The Perimeter Yard Indicator is AA (LUC Section 3.2.6.4).

The request for variance is for a reduced setback and driveway length along the east property line. The variance request is also necessary for the detached carport in front yard. The request for the variance also includes reductions in the side yard setback.

The minimum setback is twenty (20) feet to the property line (LUC Section 3.2.6.5.A). The minimum driveway length is eighteen (18) feet to the property line from the front of the carport (LUC Section 3.2.6.5.B.2.a). The proposed driveway length is six (6) feet, ten (10) inches, to the property line.

A variance is also required for the detached carport in the front yard (LUC Section 3.2.5.3.C).

The minimum setback is the greater of six (6) feet or two-thirds (2/3) the height (H) of the structure's height facing any interior lot property line (LUC Section 3.2.6.4). The required setback for the detached carport is six (6) feet to the south property line (LUC Sections 3.2.3.1.B and 3.2.6.4). The proposed setback is two (2) feet, six (6) inches to the south property line.
03/29/2013 TERRY STEVENS ZONING REVIEW Denied P&DS TRANSMITTAL


FROM: Michael St.Paul, Planning Technician

PROJECT:
T12CM08170
1602 S. Via Elnora
Carport - attached



TRANSMITTAL: March 29, 2013


COMMENTS: the following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1).


This site is located in the R-1 zone (UDC 4.7.8). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9.

The minimum setback to the front street perimeter property line is the greater of twenty (20) feet, or one and one-half (1 ½) the height of the proposed wall ((UDC 6.4.5.C.1.a).

The DDO process may only be used to reduce the driveway length to a carport, and not to a garage (UDC Section 6.4.5.C.2.b.1.c). The minimum driveway length to the edge of a sidewalk for a carport is nineteen (19) feet (UDC Section 6.4.5.C.2.b.1). The minimum driveway length for a carport is eighteen feet to the property line (UDC Section 6.4.5.C.2.b.1.a & b).

The owner proposes a street perimeter yard setback of 8'-0". DDO required.
05/21/2013 CPIERCE1 ENGINEERING REVIEW Needs Review
05/21/2013 CPIERCE1 BUILDING-RESIDENTIAL REVIEW Needs Review
12/27/2012 MICHAEL ST. PAUL NPPO REVIEW Passed