Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T12CM08064
Parcel: 107081510

Address:
802 W JACINTO ST

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/WWM

Permit Number - T12CM08064
Review Name: RESIDENTIAL - BLDG/WWM
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/10/2013 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Denied T12CM08064
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, highlighting any changes, along with a written response to each of the notated items indicating action taken.

SCOPE OF REVIEW:
The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2006 International Residential Code, 2006 International Energy Conservation Code, and Arizona State amendments to the 2006 Uniform Plumbing Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval.

SITE PLAN:

1. Indicate the location of electrical service on the site plan, R106.1.1.

STRUCTURAL PLANS:

1. Show the rafter size and spacing of existing roof framing for verifying new load carrying capacity, R301.1. The maximum span for 2" x 12" rafters is 19' -10" rather than 20'.
2. Show a beam size with appropriate load carrying capacity, R301.1. The minimum required porch beam size is 4" x 8".

PLUMBING PLANS:

1. Show protection of (indoor rated) equipment located outdoors with an exterior rated enclosure, G2406.3. Provide a water heater enclosure.
2. Show plumbing vents (VTR) sizes consistent with Table P3107.3. Show a common vent with water closet with a 3" VTR.

ELECTRICAL PLANS:

1. Use Table E3602.13 for sizing 15, 20 & 30 AMP branch circuit conductors and protection ratings.
2. Designate the circuit number at the location of each light fixture, receptacle, appliance and equipment disconnect switch, E3603.5. Include the countertop receptacles.
3. Show all receptacle outlets within 6' of a sink with ground fault circuit interrupting protection. Label each receptacle GFCI requiring such protection, E3802.

If you have any questions please contact:
Ken Van Karsen
(520) 837-4912
City of Tucson Residential Plan Review
01/14/2013 CPIERCE1 WWM REVIEW Needs Review

Final Status

Task End Date Reviewer's Name Type of Review Description
01/14/2013 CPIERCE1 OUT TO CUSTOMER Completed