Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - TI
Permit Number - T12CM07916
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
01/15/2013 | CPIERCE1 | WWM | REVIEW | Needs Review | |
12/14/2012 | TERRY STEVENS | ZONING | REVIEW | Approved | |
12/14/2012 | LOREN MAKUS | ENGINEERING | REVIEW | Approved | |
12/14/2012 | ERIC NEWCOMB | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed | |
12/14/2012 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Denied | 1. SHEET IA1.0; KEYNOTE 11: A NOTE WILL BE ADDED TO THE PROJECT AT THIS TIME THAT THE NEW PIT LEVELERS ARE NOT INCLUDED IN THIS PERMIT. ADDITION OF THE LEVELERS AT A LATER DATE WILL REQUIRE A PERMIT REVISION AND A CHANGE IN PERMIT FEES. 2. SHEET IA1.1; PLAN: THE CITY OF TUCSON REQUIRES ALL LETTERING (UPPER AND LOWER CASE) TO BE A MINIMUM OF 3/32' IN HEIGHT. REVISE THE ELEVATION INDICATORS. 3. SHEET IA4.0; ELEVATION 1(B): PROVIDE A DIMENSION FROM THE BACK WALL TO THE VERTICAL GRAB BAR. 4. SHEET IA4.0; ELEVATION 1(B): PROVIDE A DIMENSION TO THE PAPER DISPENSER. 5. SHEET IA4.0; ELEVATION 1(A): PROVIDE A DIMENSION FROM THE SIDE WALL TO THE HORIZONTAL GRAB BAR. 6. SHEET IA4.0; RESTROOM LEGEND: THE CITY OF TUCSON REQUIRES ALL LETTERING (UPPER AND LOWER CASE) TO BE A MINIMUM OF 3/32' IN HEIGHT. 7. GENERAL: PROVIDE WRITTEN RESPONSES TO ALL REVIEW COMMENTS. |
12/14/2012 | ERIC NEWCOMB | ADA | REVIEW | Passed | |
12/17/2012 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Denied | Provide structural calculations to verify that the existing roof is capable of supporting the additional dead load due to the installation of the roof top unit. Reference: Section 302.1, IMC 2006. |
12/17/2012 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | 1. Provide structural calculations to show that the existing wall can safely support the water heater . Reference: Sections 310.0 and 314.5, UPC 2006. 2. Provide a vacuum relief for the water heater. Reference: Section 608.7, UPC 2006. 3. Provide a site plan showing the location of the building, utility services (i.e. water and sewer), and the property lines. |
12/17/2012 | ROBERT SHERRY | WATER | REVIEW | Denied | Show the location of the water meter and the backflow preventer for this building. |
12/17/2012 | KEN BROUILLETTE | FIRE | REVIEW | Approved | |
12/17/2012 | RAY MAJUTA | ELECTRICAL-COMMERCIAL | REVIEW | Approved |