Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - TI
Permit Number - T12CM07729
Review Name: COMMERCIAL - TI
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/06/2012 | MICHAEL ST. PAUL | ZONING | REVIEW | Approved | |
| 12/06/2012 | PAUL MACHADO | ENGINEERING | REVIEW | Approved | |
| 12/06/2012 | ERIC NEWCOMB | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Approved | |
| 12/06/2012 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Approved | |
| 12/06/2012 | ERIC NEWCOMB | ADA | REVIEW | Passed | |
| 12/07/2012 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Denied | 1. Provide structural calculations to verify that the existing roof is capable of supporting the additional dead load due to the installation of the roof top units and the evaporative cooler. Reference: Section 302.1, IMC 2006. 2. Revise the sequence of operation for the restroom exhaust fan so that all of the air supplied to the restrooms will be exhausted. Reference: Section 403.2.1 (4), IMC 2006. |
| 12/07/2012 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | 1. The size of a wet vent shall be a minimum of one pipe size greater than that required for the drain of the upper fixture. Reference: Section 908.2, UPC 2006. 2. Provide water service and a drain for the new evaporative cooler. |
| 12/07/2012 | ROBERT SHERRY | WATER | REVIEW | Approved | |
| 12/07/2012 | RAY MAJUTA | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
| 12/10/2012 | KEN BROUILLETTE | FIRE | REVIEW | Approv-Cond | High piled storage is not allowed unless compliance with Chapter 23 of the 2006 IFC. Sprinkler monitoring is required. The fire sprinkler system shall be designed for the type of storage and NFPA 13. Key box is required if not already on fire sprinkler riser room. |
| 12/14/2012 | GERRY KOZIOL | WWM | REVIEW | Approved |