Permit Review Detail
Review Status: Completed
Review Details: CELL TOWER/ANTENNAS
Permit Number - T12CM07618
Review Name: CELL TOWER/ANTENNAS
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/02/2013 | LEERAY HANLY | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
| 12/05/2012 | KEN BROUILLETTE | FIRE | REVIEW | Denied | Need quantities of batteries (gallons and type). Left message with Mr. Fries. Phone number on permit review card and application for contact is incorrect. |
| 12/06/2012 | MICHAEL ST. PAUL | ZONING | REVIEW | Denied | "This Ordinance becomes effective thirty (30) days after it is adopted by the mayor and Council and is availabel from the City Clerk." This Ordinance (11037) was adopted on November 20th, 2012. These plans may not be approved until December, 21, 2012. |
| 12/06/2012 | MICHAEL ST. PAUL | PLANNING-CITY HALL | REVIEW | Denied | "This Ordinance becomes effective thirty (30) days after it is adopted by the mayor and Council and is availabel from the City Clerk." This Ordinance (11037) was adopted on November 20th, 2012. These plans may not be approved until December, 21, 2012. |
| 12/06/2012 | GREGORY MCNEAL | COMMUNICATIONS | REVIEW | Approved | |
| 12/18/2012 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Denied | 1. SHEET 02; CONCRETE NOTES: NOTE 2 INDICATES ALL CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 4000 PSI. SHEET S1.1 INDICATES CONCRETE COMPRESSIVE STRENGTHS OF 3000 PSI AND 2500 PSI. COORDINATE. 2. SHEET S1.1; GENERAL STRUCTURAL NOTES (FOUNDATIONS): NOTE 1 INDICATES A SOILS REPORT WAS USED FOR THE FOUNDATION DESIGN. PROVIDE THAT REPORT FOR REVIEW. 3. SHEET S1.1 (FOUNDATIONS); SHEET S2.1 (FOUNDATION NOTES): NOTE 1 ON SHEET S1.1 INDICATES A SOIL BEARING VALUE OF 1500 PSF PER A SOILS REPORT, WHILE NOTE 3 ON SHEET S2.1 INDICATES A SOIL BEARING VALUE OF 1500 PSF BASED ON AN ASSUMED ALLOWABLE PRESSURE. COORDINATE. 4. GENERAL: REVISE THE STRUCTURAL SHEET NUMBERS (S0.1 AND S0.2) INDICATED ON SHEET 01 DRAWING INDEX TO MATCH THE SHEET NUMBERS INDICATED ON THE ACTUAL SHEETS (S1.1 AND S2.1). 5. GENERAL: PROVIDE WRITTEN RESPONSES TO ALL REVIEW COMMENTS. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 01/09/2013 | CPIERCE1 | REJECT SHELF | Completed |
| 01/03/2013 | CPIERCE1 | OUT TO CUSTOMER | Completed |