Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T12CM07499
Parcel: 13612001P

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T12CM07499
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/17/2013 JASON GREEN ENGINEERING REVIEW Denied Building Plans will be approved upon approval of DP11-0022. Once all comments have been addressed under the DP the building plans can be stamped approved at the counter.
01/23/2013 TERRY STEVENS ZONING REVIEW Denied Zoning cannot approve the building plan until the development package has been approved
01/31/2013 RONALD BROWN BUILDING-COMMERCIAL REVIEW Denied ADDITIONL REVIEW COMMENTS
SHEET A7.1
1. At detail 8, the detailed urinal shown is not accessible, too high. Please use the 17" high urinal as detailed in your installation standards. Please provide dimension.
2. Detail 5:
a. Show the 3'-0" wide dimension for the urinal stall as required by ICC A117.1, Section 605 and 305.
b. The passage to the men's water cloaet stall is not wide enough as required by ICC A117.1, Section 604.8.3. Please revise and resubmit.
END OF REVIEW
02/06/2013 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Denied 1. Comment not addressed by the architect. Provide information to show how the proposed water heater is to be supported from the building structure. Reference: Sections 106.3.1 and 301.2, IPC 2006.
2. This comment is addressing the building sewer, not the building drain. Provide an additional cleanout in the building sewer. [Original comment: Provide cleanouts in the building sewer at intervals not exceeding 100 feet. Reference: Section 708.3.2, IPC 2006.]
02/11/2013 GERRY KOZIOL WWM REVIEW Denied NEED CIVIL/UTILITY PLANS WITH BLD PLANS

Final Status

Task End Date Reviewer's Name Type of Review Description
02/13/2013 FERNE RODRIGUEZ OUT TO CUSTOMER Completed