Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/WWM
Permit Number - T12CM06891
Review Name: RESIDENTIAL - BLDG/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/30/2013 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Denied | T12CM06891 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, highlighting any changes, along with a written response to each of the notated items indicating action taken. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2006 International Residential Code, 2006 International Energy Conservation Code, and Arizona State amendments to the 2006 Uniform Plumbing Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. GENERAL REQUIREMENTS: All engineers and architects involved in the design of the structure are to seal the related sheets of plans, details and calculations in accordance with the rules of the State Board of Technical Registration. The City of Tucson adopted the 2006 IRC with amendments on 6/12/2007 and the 2006 UPC with amendments on 7/10/2007. For initial construction: Effective 1/1/2007 the Inclusive Home Design; starting 3/1/2009 Solar Water Preparation and 7/1/2009 Solar Photo-Voltaic Preparation are required for all new SFR and duplex plans. Show the code references on the plans. Amendments to adopted codes are at the City web-site http://www.tucsonaz.gov: Planning, Building, & Business; under the Building topic; Building Ordinances and Codes; Building Codes STRUCTURAL PLANS: 1. Provide a header schedule and show opening sizes consistent with Table 502.5(1) & (2). Clarify the schedule on sheet A6. SECTIONS - DETAILS - NOTES: 1. Show exterior wood siding, sheathing and wall framing with a 6" clearance above the ground, R319.1 item 5. Clarify Detail 4/A5. Weep screed has a minimum 4" clearance above grade, R703.6.2.1. 2. Show the weep screed with a minimum clearance 2" above paved areas, R703.6.2.1. Clarify Detail 1/A5. This may require a design with concrete stems. 3. Show the ceiling gypsum board as either 5/8" or ½" sag resistant when applied to 24" o/c ceiling framing, IRC table R702.3.5 footnote d. 4. Show fiber-cement board or glass mat gypsum backers for tiled walls in tub and shower areas, R702.4.2. Clarify Detail 2/A1. 5. Clarify the chimney notation on Plan A/A6 by showing a 2" clearance to combustible materials, R1001.11. PLUMBING PLANS: 1. Provide the water pipe diameter between the meter and shut off valve in compliance with UPC 610.8, Table 6-6. A minimum 1" service pipe is required for supplying water to more than 9.5 fixture units. 2. Show gas pipe sizes in compliance with connected demand, UPC 1217.2, & Table 12-8. G2413.3 & Table G2413.4(1). Provide a ¾"gas line for the range supporting a demand of 65,000 BTU at a developed length over 60'. ELECTRICAL PLANS: 1. Protect bedroom outlets including receptacles, lights and smoke detectors with combination type arc-fault circuit interrupters, E3802.12. If you have any questions please contact: Ken Van Karsen (520) 837-4912 City of Tucson Residential Plan Review |
| 02/07/2013 | GERRY KOZIOL | WWM | REVIEW | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 02/08/2013 | CPIERCE1 | REJECT SHELF | Completed |