Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - TI
Permit Number - T12CM06870
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
11/02/2012 | RONALD BROWN | BUILDING-COMMERCIAL | REVIEW | Approved | |
11/02/2012 | MARTIN BROWN | FIRE | REVIEW | Approved | |
11/06/2012 | RAY MAJUTA | ELECTRICAL-COMMERCIAL | REVIEW | Denied | T12CM06870 350 N Wilmot 1.Concerning the lighting and power sheets for Cath-1 and Cath-3, must provide circuit numbers assigned to all devices being re-fed, especially Life Safety and Critical Branch circuits. 2. All lettering and numbering must be min 3/32' text, Sheets E4-01A.2 and .3, also E4-01B.2 and .3 per City of Tucson Submittal Requirements.( For copy reasons). 3. No mention of load calculations for either of the PDU-1000 units or the 25KW UPS units other than in there individual panels, have these loads been figures for up-stream calculations ? 4. Concerning loads for H-1, AHU-1, EX-Fan 1 and 1AC-1, have these be figured into panels, if so how ? Where is 1AC-1 being fed from ? 5. Where is Room 1222 located concerning the two Cath Panels ? Ray T Majuta Electrical Plan Review PDSD, C of Tuc., 11/7/2012 Ray.Majuta@tucsonaz.gov |
11/07/2012 | STEVE SHIELDS | ZONING | REVIEW | Approved | |
11/21/2012 | ROBERT SHERRY | WATER | REVIEW | Approved | |
11/21/2012 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Approved | |
11/23/2012 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Denied | 1. Identify keynote #9, shown on detail 2/M1-01. 2. Condensate drains from air conditioning units may not terminate over a roof drain or gutter unless the roof drain or gutter terminates at or above grade in an area capable of absorbing the condensate flow without surface drainage. Reference: Section 307.2.1, IMC 2006, as amended by the City of Tucson. 3. Verify the temperature of the liquid being drained from the electric steam generator (detail 3/M8-01). Water at temperatures greater than 140 degrees Fahrenheit shall not be discharged to the sanitary drain system but shall be allowed to cool below 140 degrees Fahrenheit prior to being discharged into an indirect waste receptor connected to the sanitary drain system. Reference: Section 803.1, IPC 2006. |
12/03/2012 | GERRY KOZIOL | WWM | REVIEW | Approved |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
12/12/2012 | CPIERCE1 | REJECT SHELF | Completed |