Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: T12CM06870
Parcel: 133170630

Address:
350 N WILMOT RD

Review Status: Completed

Review Details: COMMERCIAL - TI

Permit Number - T12CM06870
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
11/02/2012 RONALD BROWN BUILDING-COMMERCIAL REVIEW Approved
11/02/2012 MARTIN BROWN FIRE REVIEW Approved
11/06/2012 RAY MAJUTA ELECTRICAL-COMMERCIAL REVIEW Denied T12CM06870
350 N Wilmot

1.Concerning the lighting and power sheets for Cath-1 and Cath-3, must provide circuit numbers assigned to all devices being re-fed, especially Life Safety and Critical
Branch circuits.
2. All lettering and numbering must be min 3/32' text, Sheets E4-01A.2 and .3, also E4-01B.2 and .3 per
City of Tucson Submittal Requirements.( For copy reasons).
3. No mention of load calculations for either of the
PDU-1000 units or the 25KW UPS units other than in there individual panels, have these loads been figures for up-stream calculations ?
4. Concerning loads for H-1, AHU-1, EX-Fan 1 and 1AC-1, have these be figured into panels, if so how ? Where is 1AC-1 being fed from ?
5. Where is Room 1222 located concerning the two Cath Panels ?

Ray T Majuta
Electrical Plan Review
PDSD, C of Tuc.,
11/7/2012
Ray.Majuta@tucsonaz.gov
11/07/2012 STEVE SHIELDS ZONING REVIEW Approved
11/21/2012 ROBERT SHERRY WATER REVIEW Approved
11/21/2012 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Approved
11/23/2012 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Denied 1. Identify keynote #9, shown on detail 2/M1-01.
2. Condensate drains from air conditioning units may not terminate over a roof drain or gutter unless the roof drain or gutter terminates at or above grade in an area capable of absorbing the condensate flow without surface drainage. Reference: Section 307.2.1, IMC 2006, as amended by the City of Tucson.
3. Verify the temperature of the liquid being drained from the electric steam generator (detail 3/M8-01). Water at temperatures greater than 140 degrees Fahrenheit shall not be discharged to the sanitary drain system but shall be allowed to cool below 140 degrees Fahrenheit prior to being discharged into an indirect waste receptor connected to the sanitary drain system. Reference: Section 803.1, IPC 2006.
12/03/2012 GERRY KOZIOL WWM REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
12/12/2012 CPIERCE1 REJECT SHELF Completed