Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/WWM
Permit Number - T12CM05479
Review Name: RESIDENTIAL - BLDG/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/31/2012 | GERRY KOZIOL | WWM | REVIEW | Approved | |
| 11/14/2012 | CLAYTON TREVILLYAN | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN REVIEW COMMENTS Date: 11-14-12 Activity: T12CM05479 Address: 1739 W San Juan Applicant: Luis & Yvonne Torres Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, along with a written response to each of the noted items indicating action taken. SCOPE OF REVIEW: The scope of this plan review includes architectural, electrical, plumbing, mechanical, and energy conservation. The purpose of this review is to verify compliance to the 2006 International Residential Code with local amendments. Other comment references may be derived from additional codes and standards adopted by The City of Tucson. All features have been checked only to the extent allowed by the submittals provided for review. All portions of this project are assumed to meet other departmental requirements, conditions, and concerns before permit approval. INCLUSIVE HOME DESIGN: 1. Provide a complete set of notes on the plan to meet the Inclusive Home Design Ordinance 10463. SECTIONS - DETAILS: 2. 3x ledger material required for masonry walls, Figure R606.11(1). PLUMBING PLAN: 3. As of 6/12/2007 the City of Tucson has adopted the 2006 UPC. Appeal to the Building Official for alternate code use. 4. Tucson Water Department limits 5/8" water meters to a maximum of 20 UPC fixture units or 15 gallons per minute. Specify a ¾" water meter on the site plan for the proposed demand. 5. All construction drawings submitted after March 1, 2009 for one- or two-family dwellings require a solar water heating system, or future installation preparation with one of the following provisions: control and ¾"water piping; 3" metallic sleeve; or an accessible attic over the water heater. 6. All construction drawings submitted after June 1, 2010 for one- or two-family dwellings must provide segregated building drains for future gray water utilization, Ordinance #10579. ELECTRICAL PLAN: 7. On June 17, 2008, Mayor and Council unanimously voted to require all new residences to be solar ready for electric (PV). Starting July 1, 2009, all new single family homes or duplexes must include in the plans either a photovoltaic system or preparation for later installation of a PV system in order to receive a permit. OUTDOOR LIGHTING CODE 8. Show compliance with City of Tucson Outdoor Lighting Code with an approved lighting calculation in accordance with OLC 3.1.2. Include all exterior fixtures on the property in the calculations. Model plans should specify a minimum lot size for the proposed exterior lighting. If you have any questions please contact: Clayton Trevillyan 520.837.4913 Residential Plan Review |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 11/19/2012 | CPIERCE1 | APPROVAL SHELF | Completed |
| 11/19/2012 | CPIERCE1 | OUT TO CUSTOMER | Completed |
| 11/19/2012 | CPIERCE1 | REJECT SHELF | Completed |