Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Active
Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/WWM
Permit Number - T12CM05429
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/WWM
Review Status: Active
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/29/2012 | MICHAEL ST. PAUL | ZONING | REVIEW | Denied | CDRC TRANSMITTAL FROM: Michael St.Paul, Planning Technician PROJECT: T12CM05429 1202 East Alta Vista Street Second Unit TRANSMITTAL: August 29, 2012 COMMENTS: the following comments are relative to an application for a Design Development Option (DDO). This site is located in the R-2 zone (LUC Section 2.3.5.2.A.2). The Development Designator is "K" (LUC Sections 2.3.5.2.A.2 & 3.2.3.1.C) and the Perimeter Yard Indicator is BB (LUC Sections 3.2.3.1.C & 3.2.6.4). A DDO is required for the proposed second unit in the rear yard. The minimum setback to the south property line is the greater of ten (10) feet or three-quarters (3/4) the height of the structure's wall, measured for design grade to the highest point (LUC Section 3.2.6.4 & Illustration 3.2.6.3). The height point of the south wall for the second unit is twelve (12) feet, four (4) inches. The required minimum setback is ten (10) feet. The proposed setback to the south property line is one (1) foot. |
| 08/29/2012 | ANY | BUILDING-RESIDENTIAL | REVIEW | Active | |
| 08/29/2012 | MICHAEL ST. PAUL | NPPO | REVIEW | Passed | |
| 08/29/2012 | ANY | WWM | REVIEW | Active | |
| 08/29/2012 | ANY | ENGINEERING | REVIEW | Active |