Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - TI
Permit Number - T12CM05125
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
08/20/2012 | LAITH ALSHAMI | ENGINEERING | REVIEW | Approved | |
08/21/2012 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Denied | 1. SHEET A.2; PLAN A: THE EXISTING DOOR ON THE EAST WALL OF THE LOBBY MUST SWING IN THE OPPOSITE DIRECTION. 2. SHEET A.2; PLAN A: PROVIDE INFORMATION ON THE DRAWING TO INDICATE ACCESSIBILITY REQUIREMENTS ARE MET FOR THE NEW RESTROOM DOOR LOCATION. 3. SHEET A.2; PLAN A: PROVIDE INFORMATION ON THE DRAWING FOR THE SERVICE SINK AS REQUIRED BY THE 2006 IBC TABLE 2902.1. 4. SHEET A.2; ENLARGED PLAN C: PROVIDE THE LOCATION OF THE VERTICAL GRAB BAR FROM THE WALL PER THE ICC/ANSI A117.1-2003, FIGURE 604.5.1. 5. GENERAL: PROVIDE WRITTEN RESPONSES TO ALL REVIEW COMMENTS. |
08/21/2012 | ROBERT SHERRY | WATER | REVIEW | Approved | |
08/21/2012 | ERIC NEWCOMB | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed | |
08/21/2012 | ERIC NEWCOMB | ADA | REVIEW | Passed | |
08/21/2012 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Approved | |
08/24/2012 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Approved | |
08/28/2012 | STEVE SHIELDS | ZONING | REVIEW | Needs Review | |
08/28/2012 | FRODRIG2 | WWM | REVIEW | Needs Review | |
08/28/2012 | FRODRIG2 | ELECTRICAL-COMMERCIAL | REVIEW | Needs Review | |
08/28/2012 | KEN BROUILLETTE | FIRE | REVIEW | Approv-Cond | 1. Exit hardware not shown. provide panic on second exit 2. Emergency egress lighting needs to be shown with exit signs types and location 3. Post or indicate occupant loads per room |