Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/WWM
Permit Number - T12CM04917
Review Name: RESIDENTIAL - BLDG/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/21/2012 | CLAYTON TREVILLYAN | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN REVIEW COMMENTS Date: 8-24-12 Activity: T12CM04917 Address: 2125 N. Euclid Applicant: David Espinose Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, along with a written response to each of the noted items indicating action taken. SCOPE OF REVIEW: The scope of this plan review includes architectural, electrical, plumbing, mechanical, and energy conservation. The purpose of this review is to verify compliance to the 2006 International Residential Code with local amendments. Other comment references may be derived from additional codes and standards adopted by The City of Tucson. All features have been checked only to the extent allowed by the submittals provided for review. All portions of this project are assumed to meet other departmental requirements, conditions, and concerns before permit approval. FLOOR PLAN: 1. Show the location of attic access min. 22"x30", R807. 2. Provide a floor or landing outside exterior doors, R311.4.3. FOUNDATION PLAN: 3. Provide a note for termite treatment, R320 as amended. SECTIONS - DETAILS: 4. Provide an attic space ventilation calculation for the existing roof area if the new addition impacts the existing eave vents, R806.2. 5. Provide a minimum opening of 22" by 30" for access and ventilation between over-framed assemblies (>30 S.F.), R807. MECHANICAL PLAN: 6. Specify combustion air openings in accordance with chapter 17 of the International Residential Code. ELECTRICAL PLAN: 7. Provide wall or floor receptacles within six feet of the doorway to addition, E3801.2. 8. Bedroom outlets shall be protected with combination-type arc-fault breakers (including lights and smoke detectors), E3802.12. If you have any questions please contact: Clayton Trevillyan 520.837.4913 Residential Plan Review |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 10/01/2012 | GERARDO BONILLA | APPROVAL SHELF | Completed |
| 10/01/2012 | GERARDO BONILLA | OUT TO CUSTOMER | Completed |
| 10/01/2012 | GERARDO BONILLA | REJECT SHELF | Completed |