Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

The login landing page when selecting 'View' is still occurring and is still pending further investigation. 

Permit Number: T12CM04716
Parcel: 133281240

Address:
8462 E 5TH ST

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING-WALKTHRU

Permit Number - T12CM04716
Review Name: RESIDENTIAL - BLDG/ZONING-WALKTHRU
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/02/2012 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Denied Denied: a ¾" pipe is undersized for supplying 170,000 BTU with a developed length of 79 feet. Consider a meter relocation, or replace all undersized pipe segments.