Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T12CM04698
Parcel: 113100990

Address:
2611 N WARREN AV

Review Status: Completed

Review Details: COMMERCIAL - TI

Permit Number - T12CM04698
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/06/2012 KEN BROUILLETTE FIRE REVIEW Approved
08/16/2012 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Denied 1. Revise the waste piping for the clinical sink, P7: the fixture schedule shows a 2" waste but the outlet of the sink has an internal diameter of 3.125". Any fitting or connection in a drainage system that results in a reduction of the pipe area is prohibited. Reference: Section 706.2, IPC 2006.
2. Provide shower control valves that comply with the requirements of Section 424.5, IPC 2006.
3. Provide a complete diagram of the natural gas distribution system showing the all of the loads, developed lengths, and the layout of the distribution piping. Reference: Section 106.3.1, IFGC 2006.
08/16/2012 ROBERT SHERRY WATER REVIEW Approved
08/17/2012 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Approved
08/21/2012 RAY MAJUTA ELECTRICAL-COMMERCIAL REVIEW Approved
08/24/2012 GERRY KOZIOL WWM REVIEW Approved
08/29/2012 LEERAY HANLY BUILDING-COMMERCIAL REVIEW Denied Please clarify if this is a nursing home, hospital, or rehabilitation facility. Accessibility reviews require this information (IBC 1107.5)

Please clarify how this facility either meets all accessibility requirements or how this scope of work conforms to IBC 3409.6 & 3409.7. (new alterations are subject to up to 20% of construction costs being applied toward more accessibility.) -- Specifically none of these rooms meet the requirements for type A dwelling units.

Please dimension your toilet rooms for verification of required clearances.

Architectural plans do not indicate medical gas installations planned to be installed within existing smoke barriers. Please provide cut sheets and details for any equipment to be located within wall cavity, and specify firestop systems for all penetrations of these walls. IBC 709, 712

PP A5 flooring in restrooms to extend 6" up walls. IBC 1210.1

PP A8 details 14,15,18 -- please clarify how you are suspending these items from the strucure above (fasteners), how vertical and horizontal elements are to be connected, and the gauge of steel used for the studs and joists.

Coordinate mechanical and architectural sheets to show compliance with IBC 710 for duct penetrations of smoke partitions.

Mechanical sheets call for fire dampers. Please coordinate with architectural pages if you are to install fire dampers. Include information for what rating you wish to maintain at the corridor wall as well as cut-sheets, installation details, and correct firestop systems.