Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T12CM04564
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/05/2012 | GERRY KOZIOL | WWM | REVIEW | Approved | |
| 09/17/2012 | CLAYTON TREVILLYAN | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN REVIEW COMMENTS Date: 09-18-12 Activity: T12CM04564 2nd review Address: 3524 E. 4th St Applicant: Gary Brummer Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, along with a written response to each of the noted items indicating action taken. SCOPE OF REVIEW: The scope of this plan review includes architectural, electrical, plumbing, mechanical, and energy conservation. The purpose of this review is to verify compliance to the 2006 International Residential Code with local amendments. Other comment references may be derived from additional codes and standards adopted by The City of Tucson. All features have been checked only to the extent allowed by the submittals provided for review. All portions of this project are assumed to meet other departmental requirements, conditions, and concerns before permit approval. FOUNDATION PLAN: 1. All exterior framed walls require continuous concrete footings min. 12"wide x 12" below per R319.1 & R403.1.6 (including carport and porch enclosures). STRUCTURAL / FRAMING PLAN: 2. Provide a complete braced wall panel layout showing panels at the ends (within 12.5') of all wall lines and additional panels centered at least every 25' between, Table R602.10.1. 3. Indicate all roof framing materials and spacing, R801.2. SECTIONS - DETAILS: 4. Provide a cross section of the accessory structure to include minimum ceiling heights, ceiling and wall insulation, and footing depth below grade, R305.1, R319.1, R403.1.6, N1102.1. PLUMBING PLAN: 5. Waste clean outs are required at the kitchen sink area UPC 707.4 W/ State amendment. ELECTRICAL PLAN: 6. Show subpanel B on riser diagram INCLUDING feeder conductors, conduit sizes, and over-current protection (with appropriate correction factors), E3605.5. 7. Provide two or more 2O-amp circuits to supply the small appliance receptacles along kitchen counter tops. Such circuits shall be GFCI protected and shall not serve other rooms (except breakfast areas, pantries, etc.), E3801.3 8. Bathroom branch circuits shall serve no other outlets, E3603.4, E3801.6. OUTDOOR LIGHTING CODE 9. Flood style lighting is not considered shielded fixtures OLC 3.1.2. Fixture must shade the bulb to a point ninety degrees from the nadir. INTERNATIONAL ENERGY CONSERVATION CODE: 10. Demonstrate compliance to minimum insulation values for the carport conversion to habitable living space, N1102.1. Minimum R-30 must be provided in the ceiling cavity. If you have any questions please contact: Clayton Trevillyan 520.837.4913 Residential Plan Review |