Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T12CM04333
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/18/2012 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Approved | |
| 10/01/2012 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Denied | Comment not addressed; provide energy code compliance as requested, for Pima County <4,000 feet elevation. Revise the calculations to accurately reflect the building shown on the drawings (e.g. cavity roof insulation instead of continuous roof insulation, correct floor area, etc.). [Original comment: Provide energy code compliance calculations for the building envelope; use the climate zone for Pima County < 4,000 feet. Provide sufficient detail on the drawings to evaluate the energy compliance of the building envelope. The information shall, as a minimum, include U-factors of the envelope systems and fenestration components, along with the R-values of the insulation and the SHGC for the fenestration. Reference: Sections 101.4 and 104.2, International Energy Conservation Code 2006.] Note: the document shall be sealed by an Arizona Registrant. |
| 10/01/2012 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | The hi-low drinking fountain (P4) specified on the plumbing fixture schedule is not shown on the plumbing plan and no water supply or drain piping is shown. The architectural floor plan now shows a water dispenser in its place but nothing is shown on the plumbing plan. Coordinate the designs. Reference: Section 106.3.1, IPC 2006 and 2902.1, IBC 2006. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 10/04/2012 | CPIERCE1 | APPROVAL SHELF | Completed |
| 10/04/2012 | CPIERCE1 | OUT TO CUSTOMER | Completed |
| 10/04/2012 | CPIERCE1 | REJECT SHELF | Completed |