Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - TI
Permit Number - T12CM04250
Review Name: COMMERCIAL - TI
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/16/2012 | STEVE SHIELDS | ZONING | REVIEW | Approved | |
| 07/16/2012 | LAITH ALSHAMI | ENGINEERING | REVIEW | Approved | |
| 07/16/2012 | ERIC NEWCOMB | ADA | REVIEW | Passed | |
| 07/16/2012 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Denied | 1. SHEET TS.1; PROJECT CODE CHECK: INDICATE ON THE PLANS (SHEET A.1) WHERE EACH SUITE (A200/D200/B200/C150) IS LOCATED. 2. SHEET A.1; FIRST FLOOR PLAN: DETAIL 4/A2 (THROUGH THE NEW WALL PARTITION) INDICATES THE PARTITION IS SUPPORTED BY METAL STUDS. PROVIDE STRUCTURAL CALCULATIONS FOR THIS SUPPORT, AND INDICATE CONNECTIONS OF THE NEW SUPPORTS TO THE EXISTING STRUCTURE. INCLUDE A STRUCTURAL ANALYSIS OF THE EXISTING STRUCTURE TO SUPPORT THIS ADDITIONAL PARTITION LOAD. 3. SHEET A.1; FIRST FLOOR PLAN: PROVIDE AN ANALYSIS TO INDICATE ONE EXIT FOR CONFERENCE ROOM-1 OR CONFERENCE ROOM-2 IS ADEQUATE WHEN SEPARATED BY THE PARTITION. 4. SHEET A.1; FIRST FLOOR PLAN: IF TWO EXITS ARE REQUIRED FOR THE CONFERENCE ROOMS (COMBINED), THE DOORS MUST BE SEPARATED PER THE IBC SECTION 1015.2.1. VERIFY. 5. SHEET A.1; PLAN 4: SINCE THE MEN'S/WOMEN'S RESTROOMS ARE BEING ALTERED, THEY MUST MEET ACCESSIBILITY STANDARDS OF THE ICC/ANSI. VERIFY. 6. GENERAL: PROVIDE GRAB BARS IN THE RESTROOMS PER ICC/ANSI FIGURES 604.5.1 AND 604.5.2. THIS WILL SATISFY THE 20% MAXIMUM COST ISSUE FOR ACCESSIBILITY. 7. GENERAL: PROVIDE WRITTEN RESPONSES FOR ALL REVIEW COMMENTS. |
| 07/16/2012 | BETH GRANT | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed | |
| 07/17/2012 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Needs Review | |
| 07/17/2012 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Needs Review | |
| 07/17/2012 | ROBERT SHERRY | WATER | REVIEW | Denied | Provide the size of the existing water meter and the reduced pressure backflow assembly. |
| 07/17/2012 | RAY MAJUTA | ELECTRICAL-COMMERCIAL | REVIEW | Needs Review | |
| 07/18/2012 | GERRY KOZIOL | WWM | REVIEW | Approved | |
| 07/18/2012 | CPIERCE1 | FIRE | REVIEW | Needs Review |