Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T12CM04248
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/18/2013 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Approved | |
| 12/18/2013 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Approved | |
| 12/20/2013 | DAVID RIVERA | ZONING | REVIEW | Approved | |
| 12/26/2013 | JASON GREEN | ENGINEERING | REVIEW | Approved | December 27, 2013 FLOODPLAIN USE PERMIT NO.: T12OT001005 ADDRESS: 829 W Silverlake Rd Tucson, Arizona 85713 OWNER: Tucson Silverlake LLC 4600 W Camelback Rd Glendale, AZ 85301 The applicant is authorized to use a portion of the City of Tucson Flood Hazard Area per the City of Tucson Flood Hazard Area delineation of the Mission View Wash, specifically described as: A portion of Parcel 118-11-010B For the purpose of constructing an elevated Commercial Building, Paved Vehicular Use Area, and Site Improvements. The applicant agrees to comply with City of Tucson Floodplain and Erosion Hazard, and Watercourse Amenities, Safety and Habitat regulations, and is particularly bound by the conditions stated below. Violation of any of the conditions stated or referred to below, as determined by the City Engineer, shall be grounds for revocation of this permit. Responsibility for renewal of this permit, if necessary, is with the applicant. Issuance of this permit does not constitute a waiver of other requirements contained in the Tucson City Code, Unified Development, or any other Federal, State, County, or local regulation. No use other than as permitted herein is allowed. Additional uses allowed under City of Tucson Floodplain and Erosion Hazard Regulations and Watercourse Amenities, Safety, and Habitat regulations require the issuance of an additional Floodplain Use Permit. This floodplain use permit is issued with the following 9 conditions: 1) This permit becomes invalid and is subject to additional floodplain review, if any required development changes the construction of the building or site improvements, or, if there is any further disturbance within the floodplain other than that outlined in this application. This floodplain use permit may be subject to conditions or restrictions designed to reduce or mitigate the potential damage or hazard to life or property resulting from new building and site improvements within the regulatory floodplain, floodway or erosion hazard areas as determined by the project engineer and accepted by the City of Tucson. 2) Except as approved by the City Engineer prior to the start of construction, development under this permit shall not obstruct, retard or divert the existing flow of floodwaters from or to adjacent properties. 3) The property is located in a mapped regulatory floodplain per the submitted Drainage Report prepared by NOE Engineering, dated 13DEC13. All work shall conform to the conditions and requirements of said report and per the approved development plan package. 4) For purposes of this permit the following flood elevations shall be used for the enclosed shed: Base Flood Elevation (BFE) = 2377.74 feet NAVD 1988 Regulatory Flood Elevation (RFE) = 2378.74 feet NAVD 1988 Building is to have lowest finished floor elevated at or above the Regulatory Flood Elevation (RFE) and lowest point of any attached appliances is to be at or above the Regulatory Flood Elevation (RFE). 5) Floodplain Approval of elevation certificate, prepared by an Arizona State Registered Land Surveyor, is required prior to the 1010/1015 inspection (P2S) and prior to finished construction or Final Inspection (P2F). The Elevation Certificate must include the identity and elevation of the lowest service equipment/machinery servicing the building as well as the identity and location of all other equipment/machinery servicing the building. 6) Within 5 (five) days of issuance of this permit, and through completion of the project, notification must be posted and maintained in a conspicuous place on the job site stating "CONSTRUCTION PROCEEDING UNDER REQUIREMENTS OF CITY OF TUCSON FLOODPLAIN USE PERMIT # T12OT01005 FOR INFORMATION PLEASE CALL 791-5550." 7) Any additional future disturbance of the floodplain shall have separate floodplain use permit applications submitted to this office for review and approval. 8) All work shall conform to the approved site plan, T12CM01005, which is made part of this permit. 9) This permit is specific to the improvements for 829 W Silverlake Rd as indicated on the approved plans. It shall not apply to any other structure or property, whether attached or unattached, not specified under this permit. This Floodplain Use Permit will be automatically revoked and becomes invalid if conditions are not complied with, as set forth in this permit. APPLICANT NAME: Cornell Architecture ADDRESS: 2558 W Roughrider Rd Phoenix, Arizona 85087 PHONE: 1-623-465-4507 CONTRACTOR: Skyline Builders & Restoration Inc. ADDRESS: 2401 N 24th Avenue Phoenix, Arizona 85009 PHONE: 1-602-404-0843 (EXPIRATION DATE) Month: 12 Day: 27 Year: 2014 SIGNATURE OF APPLICANT DATE The applicant is authorized by the City Engineer to receive a floodplain use permit subject to the above referenced conditions and restrictions. |