Permit Number: T12CM04248
Parcel: 11811010B

Review Status: Completed

Review Details: COMMERCIAL - NEW

Permit Number - T12CM04248
Review Name: COMMERCIAL - NEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/19/2012 KEN BROUILLETTE FIRE REVIEW Approv-Cond Approval is conditioned on second fire hydrant available near the site. Fire Sprinklers may be required if second hydrant is not available. DP12-0099 was denied because second fire hydrant was not shown.
07/20/2012 JASON GREEN ENGINEERING REVIEW Denied Building plan will be approved after approval of the DP Package (DP12-0099).
07/24/2012 RONALD BROWN BUILDING-COMMERCIAL REVIEW Denied GENERAL
1. Where office areas are to recieve 5/8" plywood decking above ceiling, provide signage to the effect that no storage is allowed on this decking.
2. At details aa/A6 and 4/D1, please provide 1 accessible window as per ICC A117.1, Section 904.
3. Detail 1/A6, please indicate a 3'-0" wide dimension for both urinal stalls.
END OF REVIEW
07/30/2012 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Denied 1. SEE SHEET P-2 DETAIL 1. REFERENCE: 707.4 2006 UPC. EXCEPTION ONE. CLEANOUTS MAY BE OMITTED ON A HORIZONTAL DRAIN LINE LESS THAN FIVE FEET IN LENGTH, UNLESS SUCH LINE IS SERVING SINKS OR URINALS. pROVIDE FULL SIZE CLEANOUT FOT P-5 MOP SINK. 2. SEE SHEET P-2 DETAIL ONE. REFERENCE: TABLE 7-5 2006 UPC. MINIMUM SIZE VENT FOR A WATER CLOSET IS TWO INCHES. MINIMUM SIZE VENT FOR A MOP SINK IS TWO INCHES. MINIMUM SIZE VENT FOR A URINAL IS TWO INCHES. 3. SEE SHEET TWO DETAIL ONE. REFERENCE: 908.0 2006 UPC. VERTICAL WET VENTING. SHOW THE DRAIN SIZE BETWEEN THE URINAL AND THE WATER CLOSET ON THE WET VENTED SECTION.
07/30/2012 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Denied 1. Provide structural calculations to verify that the existing roof is capable of supporting the additional dead load due to the installation of the roof top units. Reference: Section 302.1, IMC 2006.
2. Revise detail 2/MP1 to eliminate elements that do not apply to the installation of the evaporative coolers on a standing seam metal roof. Reference: Sections 106.3.1 and 302.1, IMC 2006.
07/30/2012 ROBERT SHERRY WATER REVIEW Approved
08/03/2012 RAY MAJUTA ELECTRICAL-COMMERCIAL REVIEW Approved
08/08/2012 STEVE SHIELDS ZONING REVIEW Denied PDSD TRANSMITTAL

FROM: Steve Shields
Lead Planner

PROJECT: Discount Cab
T12CM04248
Building Plan (1st Review)

TRANSMITTAL DATE: August 8, 2012

1. The building plan has been reviewed by Zoning Review Section but cannot approve the plan until all zoning comments or concerns have been addressed.

2. Zoning can not approve the building plan until the development package has been approved.

3. Zoning will re-review the building plan on the next submittal to insure compliance with the approved development package. Additional comments may be forthcoming.

If you have any questions about this transmittal, please contact me at
08/20/2012 GERRY KOZIOL WWM REVIEW Denied 1. TOTAL TRANSIT- OFFICE MAINTENANCE BUILDING #2
2. CONNECTING TO EXISTING ON-SITE PRIVATE SEWER
3. $4066.00 CREDIT GIVEN FOR REMOVAL OF 3/4 WATER METER AND INSTALLING 1-1/2" WATER METER PER COT DP PACKAGE #11-053
4. NEED ADDRESSSING REVIEW/MICHELENE- 740-6480 TO ADD BUILDING #2 - NEED SITE PLAN SUBMITTAL & NEED TO PAY $75.00
08/21/2012 JEFF DRUMM LANDFILL REVIEW Approved LF ORDINANCE OIL

Final Status

Task End Date Reviewer's Name Type of Review Description
08/22/2012 FERNE RODRIGUEZ OUT TO CUSTOMER Completed