Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: T12CM04145
Parcel: 111061620

Address:
2860 N DODGE BL

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T12CM04145
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/24/2012 CLAYTON TREVILLYAN BUILDING-RESIDENTIAL REVIEW Denied PLAN REVIEW COMMENTS
Date: 8-28-12
Activity: T12CM04145
Address: 2860 N. Dodge Blvd
Applicant: Brian Goharriz

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, along with a written response to each of the noted items indicating action taken.

SCOPE OF REVIEW:
The scope of this plan review includes architectural, electrical, plumbing, mechanical, and energy conservation. The purpose of this review is to verify compliance to the 2006 International Residential Code with local amendments. Other comment references may be derived from additional codes and standards adopted by The City of Tucson. All features have been checked only to the extent allowed by the submittals provided for review. All portions of this project are assumed to meet other departmental requirements, conditions, and concerns before permit approval.

GENERAL REQUIREMENTS:
1. Provide minimum 3/32" lettering per Development Standards or submit an appeal to the Building Official.

SITE PLAN:
2. Specify the location of electrical feeders to the new living area, R106.1.1.
3. Specify the location of water supply lines to the new living area.
4. Specify the location of the building drain from the new living area.

FLOOR PLAN:
5. Clarify schedule for size of door labeled 'D1' (6 feet-0 inches wide?)

STRUCTURAL / FRAMING PLAN:
6. Provide roof framing designed to support proposed rafter span, R801.2.
7. Provide a bond beam at the top of the proposed masonry stem wall with two continuous #4 bars.
8. Provide a complete braced wall panel layout showing panels at the ends (within 12.5') of all wall lines and additional panels centered at least every 25' between, Table R602.10.1. All exterior wall lines shall be braced and parallel interior wall lines shall be braced at intervals not exceeding 35' from exterior wall lines, R403.1.6, R602.10.1.1, R602.10.8.
9. Specify the location of roof mounted mechanical equipment and size roof framing accordingly.

ELEVATIONS:
10. Specify roof slope, R905. (Note: asphalt shingle roof assemblies require a minimum 2:12 pitch)

SECTIONS - DETAILS:
11. Clarify weather protection of wall elements between bottom of stucco applied wall finish and top of supporting stem wall.

PLUMBING PLAN:
12. Provide a water supply fixture unit schedule for the entire property (including existing) P2903.6.

MECHANICAL PLAN:
13. Provide a manufacturer cut-sheet for the proposed mechanical unit (specified model not found)
14. Provide consistent information between mechanical and electrical sheets for mechanical unit over-current requirements.
15. Specify the location of rigid mechanical ducts (above or below rafters?)
16. Show supply and return air ducts with a minimum R-8 insulation when located outside the thermal envelope, R1103.2.1.

ELECTRICAL PLAN:
17. Bathrooms require a separate 20-amp circuit, E3603.4, E3801.6. (Note: receptacles in other areas of the home may not share the bathroom circuit)
18. Provide riser diagrams for both the main panel and the sub-panel with feeder conductors, conduit sizes, and over-current protection (with appropriate correction factors), E3605.5.

OUTDOOR LIGHTING CODE
19. Provide cut sheets for all FCO fixtures showing the angle of cutoff, light emissions and fixture wattage. All other fixtures are assumed to be unshielded (non-FCO style).

INTERNATIONAL ENERGY CONSERVATION CODE:
20. Clarify ceiling insulation. Fiberglass insulation is over 9 inches thick for R-30 and the proposed cavity is 5.5 inches.

If you have any questions please contact:
Clayton Trevillyan
520.837.4913
Residential Plan Review