Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/WWM
Permit Number - T12CM04098
Review Name: RESIDENTIAL - BLDG/WWM
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
07/11/2012 | MICHAEL ST. PAUL | ZONING | REVIEW | Approved | Approval by the Design Review Board is required. |
07/12/2012 | GERRY KOZIOL | WWM | REVIEW | Approved | |
07/19/2012 | MICHAEL ST. PAUL | DRB | REVIEW | Approved | |
07/25/2012 | CLAYTON TREVILLYAN | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN REVIEW COMMENTS Date: 7-31-12 Activity: T12CM04098 Address: 189 S Avenida Del Semerador Applicant: Tom Wuelpern Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, along with a written response to each of the noted items indicating action taken. SCOPE OF REVIEW: The scope of this plan review includes architectural, electrical, plumbing, mechanical, and energy conservation. The purpose of this review is to verify compliance to the 2006 International Residential Code with local amendments. Other comment references may be derived from additional codes and standards adopted by The City of Tucson. All features have been checked only to the extent allowed by the submittals provided for review. All portions of this project are assumed to meet other departmental requirements, conditions, and concerns before permit approval. FLOOR PLAN: 1. Specify safety glazing in hazardous locations, R308.4. Within 24" of doorways. 2. The walls and soffit of the enclosed space under stairs shall be protected on the enclosed side with ½" gypsum board, R311.2.2. 3. Clarify window sizes and operation type on window schedule for windows: A, B, C, and F. ELECTRICAL PLAN: 4. Show the location of the panel with a 30"W x 36"D clear working space, E3305.2, E3501.6.2. Plan shows a 36"W x 30"D working space. 5. Clarify conductor sizes for water heater circuit. If you have any questions please contact: Clayton Trevillyan 520.837.4913 Residential Plan Review |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
08/01/2012 | CINDY AGUILAR | OUT TO CUSTOMER | Completed |