Permit Number: T12CM03813
Parcel: 141011530

Address:
5278 S CIVANO BL

Review Status: Completed

Review Details: COMMERCIAL - TI

Permit Number - T12CM03813
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/27/2012 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Approved
06/27/2012 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Passed
06/27/2012 RAY MAJUTA ELECTRICAL-COMMERCIAL REVIEW Approved
06/27/2012 ROBERT SHERRY WATER REVIEW Approved
06/27/2012 BETH GRANT COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Passed
06/27/2012 JASON GREEN ENGINEERING REVIEW Approved
06/27/2012 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Approved
06/27/2012 ERIC NEWCOMB ADA REVIEW Passed
08/14/2012 MICHAEL ST. PAUL ZONING REVIEW Denied CDRC TRANSMITTAL


FROM: Michael St.Paul, Planning Technician

PROJECT:
DP12-0123 (T12CM03813)
5278 S Civano Blvd
Conversion of first floor of SFR to Food Service, and
second and third floors to be single-family residence.


TRANSMITTAL: August 6, 2012


COMMENTS: This project is review per Development Standards Number 2-01 for a Development Package. Please attach a response letter with the next submittal, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.


1) This site is located in the Neighborhood Center District of Civano I (F-3.3.1). The Zone is PAD 12. The use is Food Service, under the Commercial Services Use Group (F-3.3.1.a) and is subject to Section 3.5.4.6.D in the Land Use Code.

2) This project is with PAD 12. Provide a reduced-scale map of the PAD District on the plan. Indicate the location of the site being developed on the map (DS 2-01.3.6).

3) Cleary depict all existing a proposed utilities on the site plan (DS 2-01.3.7.D).

4) Show on-sit pedestrian circulation as required by the LUC (3.2.8.4.B) and design criteria in Development Standard 2-08.0 and the Uniform Building Code (DS 2-01.3.9.R). Within the pedestrian circulation path, an accessible route is required (DS 2-08.3.1).

5) The minimum bicycle parking required is two (2) short term (FKA Class 2) Food Service (LUC Section 3.3.8) with a forty percent (40%) increase in Civano Neighborhood I (Civano 1 F- 3.4) for a total of three (3) short-term bicycle parking spaces required (SD2-01.3.9.H.5.d). Revise the parking calculations. Provide the parking calculation sheet in the same size as the site plan (24 by 36 inches).

6) Provide a copy of the floor plan for the restaurant and the residence (2-01.3.7.8.a). Are the patios to be used as outdoor dinning?

Note: Additional comments may be necessary relative to information provided on future submittals.
08/30/2012 GERRY KOZIOL WWM REVIEW Approved
08/30/2012 CPIERCE1 FIRE REVIEW Needs Review