Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T12CM03444
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/01/2012 | KEN BROUILLETTE | FIRE | REVIEW | Approv-Cond | No occupancy is allowed until fire code official appeal is approved form main entrance. 1. Emergency egress lighting and exit signage shall be provided and will be tested at final fire inspection. |
| 10/04/2012 | RONALD BROWN | BUILDING-COMMERCIAL | REVIEW | Denied | SHEET A0.2, DETAIL1 1. The occupant load scedule for the restaurant shows 179 whereas the floor plan shows 113+4=117. Please reconcile. 2. The open bar total occupant load shows 56+2+1=59 which requires two exits. The exiting plan shows only one exit for 35 occupants. Where do the other 24 occupants exit? 3. The fenced in patio area shows an occupancy load of 53+7=60. In addition 21 occupants are exiting through the court yard from the restaurant plus the garage missing 24 which equals 105. Two exits are required from the court yard. Please provide another exit as there is only one shown. 4. Twelve occupants are shown reentering the restaurant as an exit route. This is a non-compliant exit procedure. END OF REVIEW |
| 10/11/2012 | STEVE SHIELDS | ZONING | REVIEW | Denied | PDSD TRANSMITTAL FROM: Steve Shields Lead Planner PROJECT: Reilly Craft Pizza - Expansion - Beer Garden T12CM03444 Building Plan (2nd Review) TRANSMITTAL DATE: October 11, 2012 1. The building plan has been reviewed by Zoning Review Section but cannot approve the plan until all zoning comments or concerns have been addressed. 2. This comment has not been addressed. Based on a prior patio, use area, expansion of 1,250 sq. ft. and the proposed expansion of use into an existing garage of 1,258 sq. ft. the cumulatively expansion, 49.6% is greater than 25%. Provide an expansion calculation on the plan. 3. This comment has not been addressed. As an expansion of use is proposed provide a site plan that meets the requirements of D.S. 2-01.0. 4. This comment has not been addressed. Once the DRB is approved provide the DRB number, date of approval and any conditions of approval on the site plan. Either a Development Review Board (DRB), LUC Section 2.8.10.4, or a Downtown Infill Incentive District (IID), LUC Section 2.8.12, review is required prior to approval of the site and building plans. Contact Russlyn Wells @837-4948 for DRB review requirements. 5. This comment has not been addressed. Historic will need to approve and stamp the drawings prior to approval by zoning. Historic review is required for this project prior to approval of the site and building plans. Contact Frank Podgorski @837-4962 for historic review requirements. 6. Zoning will re-review the building plan on the next submittal to insure compliance with the approved site plan. Additional comments may be forthcoming. If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956 |
| 10/17/2012 | ROBERT SHERRY | WATER | REVIEW | Approved | |
| 10/17/2012 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | The revised riser diagram still does not show the 3" GCO that is shown on the plumbing floor plan. [Original comment: Show the proposed floor cleanouts (on plumbing floor plan) on the riser diagram.] |