Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T12CM03176
Parcel: 125060640

Address:
2147 E 5TH ST

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO

Permit Number - T12CM03176
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/26/2012 STEVE SHIELDS ZONING REVIEW Denied PDSD Zoning Review Transmittal

TO: Planning and Development Services Department
Plans Coordination Office

FROM: Steve Shields
Lead Planner

PROJECT: T12CM03176
2147 E. 5th Street

TRANSMITTAL DATE: July 26, 2012

Proposed Project: Addition of Front and Rear Porch

COMMENTS:
Site Plan OK D.D.O. required for: Side street and west perimeter yard setback from the proposed front porch addition.

Per LUC Section 3.2.6.4, R-1 Zone, Development Designator "G", Perimeter Yard Indicator "AA" the required perimeter yard setback is 6.0' or 2/3 the height of the exterior wall.
1. Based on an exterior wall height of less than 9.5" the required perimeter yard setback from the proposed room addition to the west property line is 6.4', proposed setback is 1.3'.
2. Per LUC Section 3.2.6.5.A Within established areas, the front street perimeter yard is twenty (20) feet or one and one-half (1 1/2) the height of the proposed wall (H), measured from the street property line, whichever is greater, up to a maximum of ninety (90) feet. Where a lot abuts more than one (1) street, the owner shall choose which street lot line is the front lot line. From other than the front lot line, the side street perimeter yard is ten (10) feet. Required side street setback is 10.0, proposed side street perimeter yard setback is 9.58'

If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov (520) 837-4956
11/16/2012 SPOWELL1 ENGINEERING REVIEW Needs Review
11/16/2012 SPOWELL1 NPPO REVIEW Needs Review
11/16/2012 SPOWELL1 BUILDING-RESIDENTIAL REVIEW Needs Review