Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: T12CM02811
Parcel: 115044910

Review Status: Completed

Review Details: REVISION - - 3RD

Permit Number - T12CM02811
Review Name: REVISION - - 3RD
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/26/2013 RONALD BROWN BUILDING-COMMERCIAL REVIEW Needs Review This is Leeray's project. All as-builts go to him for review and approval.
09/26/2013 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Needs Review This is Leeray's project. All as-builts go to him for review and approval.
09/26/2013 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Needs Review This is Leeray's project. All as-builts go to him for review and approval.
10/01/2013 RAY MAJUTA ELECTRICAL-COMMERCIAL REVIEW Denied T12CM02811
1020 N Tyndall Av
Tyndall Project

Provide a detailed report showing the following :
1. Identify sheet modification has been made
2. Give a short precise description of the modification
3. Reason modification made
4. If substitution made, provide a description of type material or equipment changed and installed in place
5. If modification involves another sheet---indicate.
6. Describe changes to clouded areas

As-Built changes are to be reviewed so as to be in accordance with The National Electrical Code & City Amendments the original plans approved under.
Hand written items on As-Built drawings to be removed and changes approved by EE of record or his representative.
Other items of concern are changes (hand written) in panel schedules which do not reflect loads or loads totals in panels. There appears to be several panels which have
smoke detectors and fire dampers added, how would these be reflected on the Fire alarm system and drawings.
If different types of lighting fixtures used, how is the IECC Lighting Report affected.
There is a hand written note on Sheet E-500 indicating the Fire Pump size has been changed with reference to RIF-224.
Changes on the Fire Pump should have been made through a Revision with approval prior to replacement.
Sheet E-502 has a large clouded area showing deletion of a load calculation, no further explanation given.
The panel schedules on Sheets E-503--510 have had hand written circuitry added in without load changes.
Sheet E-510 indicates SES H entire load calculation changed, no explanation on sheet, also Distribution Board DR is clouded no explanation.
This review may not include all modifications please review and address all modifications.

Ray T Majuta
Elect Plan Review
PDSD, City of Tucson
10/1/2013
Ray.Majuta@tucsonaz.gov
520-837/4988

Final Status

Task End Date Reviewer's Name Type of Review Description
10/04/2013 CPIERCE1 OUT TO CUSTOMER Completed