Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T12CM02749
Parcel: 116160110

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T12CM02749
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
11/28/2012 MICHAEL ST. PAUL ZONING REVIEW Denied Provide DDO plans.
11/29/2012 JASON GREEN ENGINEERING REVIEW Denied DATE: November 30, 2012
SUBJECT: 1011 N Van Alstine St- 2nd Engineering Review
TO: Alex Enoch
LOCATION: T14S R13E Sec11 Ward 1
REVIEWERS: Jason Green, CFM
ACTIVITY: T12CM02749


SUMMARY: Engineering Division of Planning & Development Services Department has received and reviewed the site plan application (T12CM02749) and Floodplain Use Permit (T12OT00991) for the above referenced property and does not recommend approval of the site plan at this time.

The subject property is located within a mapped FEMA Special Flood Hazard Area Zone AO1 per the Flood Insurance Rate Maps 04019C2276L the following information is required prior to site plan review:


SITE PLAN:

1) TC Sec.26-5.3: Revise the site plan and all associated cross sections to clearly label and dimension the method of elevation and all construction aspects for the proposed single family residence. Clearly dimensions stem wall design along with the required openings in the proposed crawl space. Coordinate with the Residential Review comments for design of flood vents versus air vents. The flood vents shall provide a total net area of not less than one square inch for every square foot of area enclosed, excluding any bars, louvers, or other covers of the opening. Verify that the stem wall detail shows construction aspects of the openings within the mono pour.

2) TC Sec.26-5.3: The bottom of the openings must be no higher than one foot above the higher of the exterior or interior grade. Revise the label on the site plan to state; "10"x24" opening in crawl space, bottom of opening to be no more than 1' A.F.G." for clarity purposes.


GENERAL COMMENTS:

Please provide a revised site plan that addresses the comments provided above. For expedite purposes the site plan can be reviewed over the counter (PDSD Engineering Division comment only) for stamp approval once all items have been addressed. Please call to schedule an appointment when ready.

For questions or to schedule a meeting I can be reached at 837-4929.


Jason Green, CFM
Senior Engineer Associate
Engineering Division
Planning & Development Services Department
12/07/2012 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Denied T12CM02749
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, highlighting any changes, along with a written response to each of the notated items indicating action taken.

SCOPE OF REVIEW:
The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2006 International Residential Code, 2006 International Energy Conservation Code, and Arizona State amendments to the 2006 Uniform Plumbing Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval.

GENERAL REQUIREMENTS:
Show corrections and revisions on original tracings or a finished reproducible set. Return two sets along with a set of the first submission for reference. Pen or pencil corrections on final prints will not be acceptable. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and notate sheets. (Do not cloud the changes made for comment revisions). Incorporate changes on originals and provide two copied sets for review.

All engineers and architects involved in the design of the structure are to seal the related sheets of plans, details and calculations in accordance with the rules of the State Board of Technical Registration.

STRUCTURAL PLANS:

1. Provide a roof framing plan with joist sized with appropriate load carrying capacity, R301.1. The 230 series 16" joist at 12" OC is over span. Show a series or size capable is supporting 40 PSF live and 15 PSF dead loading with 25.5' spanning.

If you have any questions please contact:
Ken Van Karsen
(520) 837-4912
City of Tucson Residential Plan Review
12/14/2012 GERRY KOZIOL WWM REVIEW Denied NEED TO SHOW PVT SEWER FROM
1010 N ANITA AND RECORDED EASEMENT DOCUMENTATION

G.KOZIAL -PCWW 12/13/12

Final Status

Task End Date Reviewer's Name Type of Review Description
12/19/2012 CPIERCE1 OUT TO CUSTOMER Completed
12/19/2012 CPIERCE1 REJECT SHELF Completed