Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/WWM
Permit Number - T12CM02692
Review Name: RESIDENTIAL - BLDG/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/01/2012 | GERRY KOZIOL | WWM | REVIEW | Approved | |
| 06/13/2012 | CLAYTON TREVILLYAN | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN REVIEW COMMENTS Date: 6-14-12 Activity: T12CM02692 Address: 4617 E Bermuda Applicant: Lisa Duron Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, along with a written response to each of the noted items indicating action taken. SCOPE OF REVIEW: The scope of this plan review includes architectural, electrical, plumbing, mechanical, and energy conservation. The purpose of this review is to verify compliance to the 2006 International Residential Code with local amendments. Other comment references may be derived from additional codes and standards adopted by The City of Tucson. All features have been checked only to the extent allowed by the submittals provided for review. All portions of this project are assumed to meet other departmental requirements, conditions, and concerns before permit approval. GENERAL REQUIREMENTS: 1. Provide minimum 3/32" lettering per Development Standards or submit an appeal to the Building Official. 2. As of 6/12/2007 the City of Tucson has adopted the 2006 IRC. All plan pages should reference this code. Appeal to the Building Official for use of the UMC or 2003 IRC. FOUNDATION PLAN: 3. Specify foundation hold-downs for alternate brace wall panels that have minimum uplift capacity of 1800 lbs, R602.10.6. Simpson PAHD42 do not qualify. STRUCTURAL / FRAMING PLAN: 4. Specify header sizes for the windows located on the east wall of the second floor. 5. Provide sufficient roof area next to second floor walls or provide roofing material on exterior wall covering, R903.1. ELEVATIONS: 6. Provide chimneys minimum 2' above any roof point within 10', not less than 3' above penetration, R1003.9. PLUMBING PLAN: 7. Specify the manufacturer and listing of the diverter valve for use with gray water systems inside buildings. 8. Washing machine gray water discharge must terminate out exterior wall above grade, Ordinance #10579 9. Remove black water drain lines for gray water fixtures, Ordinance #10579 ELECTRICAL PLAN: 10. Show receptacle outlets at each kitchen counter space wider than 12" so that no point along the wall line is more than 24" from a receptacle outlet, E3801.4.1. 11. Bathrooms require a separate 20-amp circuit with receptacles within 3' of the basin, E3603.4, E3801.6. (Exterior receptacles may not share bath circuit) 12. GFCI protection required at all garage receptacles, E3802. OUTDOOR LIGHTING CODE 13. Provide cut sheets for all FCO fixtures showing the angle of cutoff, light emissions and fixture wattage. All other fixtures are assumed to be unshielded (non-FCO style, including flood lighting). If you have any questions please contact: Clayton Trevillyan 520.837.4913 Residential Plan Review |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 06/15/2012 | CPIERCE1 | OUT TO CUSTOMER | Completed |