Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - TI
Permit Number - T12CM02450
Review Name: COMMERCIAL - TI
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/07/2012 | RONALD BROWN | BUILDING-COMMERCIAL | REVIEW | Denied | 1. Please provide a completed two part certification form for the special inspectors required for this project. Please present to the structural building reviewer for approval prior to submittal. 2. Please provide structural claculations for the structural modifications made to this structure. END OF REVIEW |
| 09/12/2012 | RMYERS1 | WATER | REVIEW | Approved | |
| 09/12/2012 | RICK MYERS | PLUMBING-COMMERCIAL | REVIEW | Denied | 1. Cover sheet shows 2006 UPC. 2. See sheet P0.0- General Plumbing Notes: Sanitary and Vent Systems #5 is in reference to 2006 IPC 708.3.3. This plan is beng reviewed per the 2006 UPC. 3. See sheet P1.0 Detail One- Restroom Waste and Vent Piping: Will require a full size clean-out for the four inch branch piping connecting to the existing four inch building drain. For clarification of pipe sizes, include the size of each section or branch, for both the plan view, and the isometric. 4. See sheet P1.0 Detail Two: Vent for the WC-2s starts out 3", and then reduces to 2" overhead. A vent may not be reduced. Reference: 905.4 2006 UPC. 5. See sheet P1.0 detail four: Restroom Domestic Water Isometric. Include the pipe sizes for each section or branch. 6. Provide the water calculations for the existing building, and show how the new demand is being accounted for. |
| 09/17/2012 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Approved | |
| 09/17/2012 | STEVE SHIELDS | ZONING | REVIEW | Denied | PDSD TRANSMITTAL FROM: Steve Shields Lead Planner PROJECT: McDonald's - 2525 S. Craycroft Road T12CM02450 Building Plan (1st Review) TRANSMITTAL DATE: September 17, 2012 1. The building plan has been reviewed by Zoning Review Section but cannot approve the plan until all zoning comments or concerns have been addressed. 2. Zoning can not approve the building plan until a development package has been approved. 3. Zoning will re-review the building plan on the next submittal to insure compliance with the approved development package. Additional comments may be forthcoming. If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956 |
| 09/19/2012 | GERRY KOZIOL | WWM | REVIEW | Approved | |
| 09/24/2012 | RAY MAJUTA | ELECTRICAL-COMMERCIAL | REVIEW | Denied | T12CM02450 2525 S Craycroft The City of Tucson has adopted begining 02/07/2012 Outdoor Lighting Code Ord #10963. All changes to any outdoor lighting site or building, must comply with this ordinance. The ordinance requires for each fixture type to indicate if it is 1. Full Cut Off, fully shielded or 2. un- shielded as defined per ordinance 3. lumen output per watts of lamps to be used 4. Option of lighting to be used per Table 401.1 of the ordinance 5. a show of compliance in order to obtain a permit for outdoor lighting. The ordinance requires allowed lumen output in ratio to size of property according to the option chosen. The ordinance can be found on The City of Tucson Website,Departments,Building Codes, OutDoor Lighting Code. Exposed LED lighting is also covered and it's lumen output to be included in this count. Please review the ordinance and show compliance,any questions call or email as shown below. Ray T Majuta Elect Plan Review PDSD, C of Tuc 9/26/2012 520-837-4988 Ray.Majuta@tucsonaz.gov |
| 10/02/2012 | PAUL MACHADO | ENGINEERING | REVIEW | Denied | See comments under DP12-0101. PM. 10-02-12. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 10/19/2012 | FERNE RODRIGUEZ | OUT TO CUSTOMER | Completed |
| 10/19/2012 | FERNE RODRIGUEZ | REJECT SHELF | Completed |