Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/ZONING-WALKTHRU
Permit Number - T12CM02372
Review Name: RESIDENTIAL - BLDG/ZONING-WALKTHRU
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/02/2012 | DAVID RIVERA | ZONING | REVIEW | Approved | FROM: David Rivera Principal Planner PROJECT: Activity No: T12CM02372 Site Address: 3937 E 27th Street Project: Additions: Carport, storage room, front porch, rear porch, and enclosure of carport to bedroom, laundry and bath room. TRANSMITTAL DATE: May 2, 20012 COMMENTS: Please resubmit DDO approved drawings along a DDO approval letter to zoning for review and permit approval. Prior to approval of the plot and building plans a building setback variance approval through the Design Development Option process is required, to allow the proposed building setbacks of 3 (three) feet along the east property line for a attached carport and storage shed. The structures were constructed without permits by the previous owner. The new owner is trying to rectify the violation and permit the structures as mentioned in the comments section above. 1. A DDO is required for to allow the 3' (three-foot) building setback for the carport and storage shed along the east property line. The exterior building wall height is listed as 7'-2" tall. The required building setback is based on the greatest of (six feet or 2/3rds) the height of the existing height of the exterior wall. The minimum building setback required is six (6) feet. LUC section 2.2.6.4 perimeter yard matrix designator (AA) adjacent to R-1, the greatest of six (6) or 2/3 the height of the wall. It is recognized by the Zoning Review Section that this site has been accepted as non-conforming for two (2) units on an R-1 Property with less than 10,000 square feet. A letter by the zoning administrator staff (William Balak) has established the non-conforming status per a letter dated 10-31-2007. Per discussion with management, the proposed or illegally built structures will not cause a loss of non-conforming status of the use. The expansion does not create an additional unit and does not create additional bedrooms that would require compliance with Performance Criteria 3.5.7.1. Any additional expansion could create a loss of non-conforming status. If you have any questions about this transmittal, please call David Rivera, (520) 837-4957. |
| 05/02/2012 | DAVID RIVERA | NPPO | REVIEW | Passed | |
| 07/26/2012 | PAUL MACHADO | ENGINEERING | REVIEW | Approved | |
| 08/22/2012 | CLAYTON TREVILLYAN | BUILDING-RESIDENTIAL | REVIEW | Approved | 1. Rafters over-spanned on garage and back porch, R801.2 2. 4x6 beam over-spanned on back and front porches, R801.2 3. Specify all ledger attachments to wall, R801.2 4. Provide a minimum ΒΌ" per 12" of slope for built-up roof assemblies, R905.9 5. Provide a fire-rated overhang on garage roof, R302 6. Specify wall anchorage to foundation 7. Provide continuous footings for exterior wood framed walls, R403.1 8. Provide a switched source of light and a GFI protected receptacle in garage, R3802.1 |