Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - TI
Permit Number - T12CM02304
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
04/30/2012 | TERRY STEVENS | ZONING | REVIEW | Denied | DEVELOPMENT PACKAGE REQUIRED |
04/30/2012 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Passed | |
04/30/2012 | RAY MAJUTA | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
04/30/2012 | ROBERT SHERRY | WATER | REVIEW | Approved | |
04/30/2012 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Denied | 1. SHEET TS1; CODE REVIEW (OCCUPANT LOADS): THE RETAIL SALES OCCUPANCY IS DETERMINED USING 100 SF/PERSON. REVISE PER THE IBC TABLE 1004.1.1. 2. SHEET TS1; CODE REVIEW (EXITING): THE CORRIDOR PROTECTION IS LISTED AS "NOT REQUIRED". IS THERE NO EXISTING CORRIDOR? VERIFY. 3. SHEET A1.0; FLOOR PLAN: A SECTION 4/A3.0 IS SHOWN ON THE PLAN, BUT THERE IS NO SECTION 4 ON SHEET A3.0. REVISE. 4. SHEET A3.0; SECTION 3: A DETAIL 7/S2.1 IS INDICATED ON THE SECTION, BUT THERE IS NO DETAIL 7 ON SHEET S2.1. REVISE. 5. SHEET A3.0; SECTION 1: THE DETAIL 3/S2.1 INDICATED ON THE SECTION IS NOT CORRECT. REVISE. 6. SHEET A3.0; SECTION 2: THE DETAIL 4/S2.1 INDICATED ON THE SECTION IS NOT CORRECT. REVISE. 7. SHEET S2.0 (FRAMING PLAN); STRUCTURAL CALCULATIONS (SHEET 5): THE CALCULATIONS INDICATE BEAM B-1 IS A 5 1/8" X 19 1/2" GLB, WHILE THE PLAN INDICATES A 5 1/8" X 18" GLB. CLARIFY. 8. SHEET S1.1; DETAIL 1: INDICATE 4 ANCHOR BOLTS ON THE LOWER BASE PLATE. 9. SHEET S1.1; DETAIL 3: CUT THIS DETAIL ON THE PLAN. 10. SHEET S1.1; DETAILS 2 AND 3: THE CITY OF TUCSON REQUIRES ALL LETTERING (UPPER AND LOWER CASE) TO BE A MINIMUM OF 3/32" IN HEIGHT. REVISE. 11. SHEET S2.1; SECTIONS 1, 2, 3, 5, AND 6: THE CITY OF TUCSON REQUIRES ALL LETTERING (UPPER AND LOWER CASE) TO BE A MINIMUM OF 3/32" IN HEIGHT. REVISE. 12. GENERAL: PROVIDE WRITTEN RESPONSES TO ALL REVIEW COMMENTS. |
04/30/2012 | RSHERRY1 | WWM | REVIEW | Passed | No new plumbing fixtures. |
04/30/2012 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Passed | |
04/30/2012 | BETH GRANT | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed | |
04/30/2012 | ERIC NEWCOMB | ADA | REVIEW | Passed | |
05/01/2012 | KEN BROUILLETTE | FIRE | REVIEW | Approved | |
05/09/2012 | CPIERCE1 | ENGINEERING | REVIEW | Needs Review |