Permit Number: T12CM01718
Parcel: 13323193C

Address:
750 N KOLB RD

Review Status: Completed

Review Details: COMMERCIAL - TI

Permit Number - T12CM01718
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/11/2012 RONALD BROWN ADA REVIEW Passed
04/13/2012 ROBERT SHERRY WATER REVIEW Approved
04/13/2012 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Passed
04/13/2012 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Passed
04/13/2012 RSHERRY1 WWM REVIEW Passed No new plumbing fixures.
04/16/2012 STEVE SHIELDS ZONING REVIEW Denied PDSD TRANSMITTAL

FROM: Steve Shields
Lead Planner

PROJECT: Guadalarjara Grill - Outdoor Patio Expansion
T12CM01718
Building Plan (1st Review)

TRANSMITTAL DATE: April 16, 2012

1. The building plan has been reviewed by Zoning Review Section but cannot approve the plan until all zoning comments or concerns have been addressed.

2. Zoning can not approve the building plan until the development package has been approved.

3. Zoning will re-review the building plan on the next submittal to insure compliance with the approved development package. Additional comments may be forthcoming.

If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956
04/17/2012 LOREN MAKUS ENGINEERING REVIEW Approved
04/23/2012 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Denied 1. SHEET TS.1; EXISTING SITE PLAN: IS THE EXISTING RESTAURANT SPRINKLERED? THE SIZE OF THE BUILDING EXCEEDS 5000 SF, THEREFORE REQUIRING SPRINKLERS. VERIFY AND INDICATE ON PLAN.
2. SHEET A.1; FLOOR PLAN: THE OCCUPANCY LOAD FOR THE PATIO IS LISTED AS 100. THIS WOULD REQUIRE TWO EXITS FROM THE PATIO. THE DOORS INTO THE EXISTING RESTAURANT (TWO THUS) DO NOT MEET THE SEPARATION DISTANCE REQUIRED (FROM THE NEW WALL GATE) BY THE 2006 IBC, SECTION 1015.2.1. PROVIDE A SECOND EXIT FROM THE PATIO.
3. SHEET A.2 (PATIO WALL DETAIL 6); STRUCTURAL CALCULATIONS (SHEETS 3, 4, AND 5): THE CALCULATIONS INDICATE AN 8" CMU WALL WITH #4 AT 16" O.C., WHILE THE DETAIL INDICATES A DIFFERENT DESIGN. CLARIFY AND REVISE THE CALCULATIONS OR THE DRAWINGS.
4. GENERAL: PROVIDE WRITTEN RESPONSES TO ALL REVIEW COMMENTS.
04/23/2012 BETH GRANT COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Approved
05/01/2012 FRODRIG2 FIRE REVIEW Needs Review Fire Code Administrator is asking ICC their interpretation of Fire Area and Occupant Load calculations as it relates to this improvement. Following the receipt of the opinion the Fire Code Administrator will make comments on this project.
05/01/2012 RAY MAJUTA ELECTRICAL-COMMERCIAL REVIEW Passed

Final Status

Task End Date Reviewer's Name Type of Review Description
05/01/2012 FERNE RODRIGUEZ OUT TO CUSTOMER Completed