Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T12CM01681
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/30/2012 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Denied | T12CM01681 R1 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, highlighting any changes, along with a written response to each of the notated items indicating action taken. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2006 International Residential Code, 2006 International Energy Conservation Code, and Arizona State amendments to the 2006 Uniform Plumbing Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. GENERAL REQUIREMENTS: Show corrections and revisions on original tracings or a finished reproducible set. Return two sets along with a set of the first submission for reference. Pen or pencil corrections on final prints will not be acceptable. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and notate sheets. (Do not cloud the changes made for comment revisions). Incorporate changes on originals and provide two copied sets for review. All engineers and architects involved in the design of the structure are to seal the related sheets of plans, details and calculations in accordance with the rules of the State Board of Technical Registration. FOUNDATION PLANS: 1. Show compliance with (soil) termite treatment, R320. 2. Locate and specify all exterior walls with a 12" minimum width and depth footing with #4 rebar for exterior wood framed walls, R403.1.1. Include all of the new Bathroom walls and the wall adjacent to the new exterior door to the TV room. 3. Show the required minimum one #4 reinforcement rebar 3" from edge in the post footer, R403.1. (City of Tucson Amended). Clarify detail #4/S2 with rebar notation. STRUCTURAL PLANS: 1. Show Carport ridge beam size with appropriate load carrying capacity, R301.1. Keynote beam #3 is undersized for 20# live and 10# dead loads. Consider a 3-1/8" x 10-1/2" glulam. SECTIONS - DETAILS: 1. Clarify Keynote listings for #3 & 4 on S2. 2. Clarify Detail labeling for #5 on S2. 3. Show a minimum ½" diameter anchor bolt at exterior wall sill plates, R602.10.8 & R403.1.6. Ram set pins are appropriate for interior patrician walls. Clarify Keynote #2/A1. 4. Clarify the location of Keynote #5 (rather than #4) at the Covered Porch on the Plan. 5. Clarify the undersized beam size shown on Section B-B/A2. Keynote #7/S3 shows a 6 x 10 beam. 6. Show a minimum 1" ventilation clearance between ceiling insulation and roof sheathing over the wall and eave area if eave vents are used, R806.3. This may be accomplished w/ baffles. If you have any questions please contact: Ken Van Karsen (520) 837-4912 City of Tucson Residential Plan Review |