Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/WWM
Permit Number - T12CM01330
Review Name: RESIDENTIAL - BLDG/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/19/2012 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Denied | T12CM01330 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, highlighting any changes, along with a written response to each of the notated items indicating action taken. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2006 International Residential Code, 2006 International Energy Conservation Code, and Arizona State amendments to the 2006 Uniform Plumbing Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. GENERAL REQUIREMENTS: Show corrections and revisions on original tracings or a finished reproducible set. Return two sets along with a set of the first submission for reference. Pen or pencil corrections on final prints will not be acceptable. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and notate sheets. (Do not cloud the changes made for comment revisions). Incorporate changes on originals and provide two copied sets for review. All engineers and architects involved in the design of the structure are to seal the related sheets of plans, details and calculations in accordance with the rules of the State Board of Technical Registration. GENERAL NOTES: " Limit all code references to those recognized by the City of Tucson. Adopted 2006 codes are listed at the Planning & Development Services web site. Show the code references used for the design. Update or remove the 1990 NEC reference on sheet #6. FOUNDATION PLANS: 1. Show compliance with termite treatment, R320. FLOOR PLANS: 1. Identify the space with window fill-in (Keynote #5/sheet 2) for R303.1 and R310 compliance. STRUCTURAL PLANS: 1. Provide the registered engineer seal on all structural plans, R602.10.10. Arizona Statute 32-144.4. 2. Show the required joist/rafter bearing contact to supporting members, R502.6 & R802.6. The fascia board may not serve as a beam, ridge board or load bearing ledger. SECTIONS - DETAILS: 1. Remove the "See Structural Calculation" notation from sheets #4 and #5, R106.1.1. Show construction requirements of all assemblies such as SWA-1 with holdown identification on the plans. ELECTRICAL PLANS: 1. Revise the electrical load calculations following Table E3502.2 for sizing 100% of the dwelling load. Apply a 40% factor for loads above 10,000 watts. Add the total nameplate for the air conditioning unit before changing VA to amperage. 2. Show receptacle outlets in garages with ground fault circuit interrupting protection, E3802. If you have any questions please contact: Ken Van Karsen (520) 837-4912 City of Tucson Residential Plan Review |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 05/01/2012 | CPIERCE1 | OUT TO CUSTOMER | Completed |