Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/WWM
Permit Number - T12CM00900
Review Name: RESIDENTIAL - BLDG/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/29/2012 | GERRY KOZIOL | WWM | REVIEW | Approved | |
| 03/30/2012 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Denied | T12CM00900 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, highlighting any changes, along with a written response to each of the notated items indicating action taken. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2006 International Residential Code, 2006 International Energy Conservation Code, and Arizona State amendments to the 2006 Uniform Plumbing Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. GENERAL REQUIREMENTS: Show corrections and revisions on original tracings or a finished reproducible set. Return two sets along with a set of the first submission for reference. Pen or pencil corrections on final prints will not be acceptable. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and notate sheets. (Do not cloud the changes made for comment revisions). Incorporate changes on originals and provide two copied sets for review. All engineers and architects involved in the design of the structure are to seal the related sheets of plans, details and calculations in accordance with the rules of the State Board of Technical Registration. FLOOR PLANS: 1. Show compliance with R310 providing the Master Bedroom open to an adjoining room per R303.2 with 50% of common wall open without doors. Enlarge the opening to the Bathroom greater than 6' wide, or provide a larger functioning Bedroom window. 2. Show the fireplaces as UL-127 compliant, R1004.1. STRUCTURAL PLANS: 1. Provide a complete floor framing plan with joist spans and ledger sizes, R301.1. 2. Notate a proposed location of the HVAC on the roof framing plan for verifying the truss load carrying capacity used for the engineered truss design, R301.1 & M1401. 3. Provide a header schedule and show existing opening sizes supporting new roof consistent with Table 502.5(1) & (2). SECTIONS - DETAILS: 1. Clarify the incomplete Kitchen area beam notation on sheet A3, R106.1.1. 2. Identify the parallel lines in the Family Room on sheet A4, R106.1.1. 3. Show exterior wood siding, sheathing and wall framing with a 6" clearance above the ground, R319.1 item 5. 4. Show fiber-cement board or glass mat gypsum backers for tiled walls in tub and shower areas, R702.4.2. 5. Show a minimum 2' termination above any roof point within 10' measured horizontally, and not less than 3' above the point where the chimney (metal pipes) passes through the roof, G2427.5.3. ELECTRICAL PLANS: 1. Revise the electrical load calculations following Table E3502.2. Add the total nameplate for the air conditioning unit the sub-total 11,760. 2. Show receptacle outlets at each kitchen counter space wider than 12" with no point along the wall line more than 24" from a receptacle outlet, E3801.4.1. Show receptacles to the left of the range and refrigerator. 3. Show exterior receptacle outlets with GFCI protection, E3802.3. OUTDOOR LIGHTING CODE 1. Show the proposed fixture as full cut-off FCO style, or provide an Outdoor Lighting Calculation including all exterior fixtures on the property for determining exterior lighting limits. If you have any questions please contact: Ken Van Karsen (520) 837-4912 City of Tucson Residential Plan Review |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 04/03/2012 | FERNE RODRIGUEZ | REJECT SHELF | Completed |