Permit Number: T12CM00405
Parcel: 130144360

Review Status: Completed

Review Details: REVISION - - 1ST

Permit Number - T12CM00405
Review Name: REVISION - - 1ST
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/09/2012 RAY MAJUTA ELECTRICAL-COMMERCIAL REVIEW Approved
07/19/2012 RONALD BROWN BUILDING-COMMERCIAL REVIEW Denied SHEET X1.0
1. Please provide accessible passenger loading zones at the "Drop Off" area indicated on the east side of the complex. As per the 2006 IBC, Section 1106.7.1, 1 accessible loading zone per every 100 linear feet is required. ICC A117.1, Section 503.3 provide the layout configuration.
07/19/2012 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
07/26/2012 CINDY AGUILAR APPROVAL SHELF Completed
07/26/2012 CINDY AGUILAR OUT TO CUSTOMER Completed