Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - TI ALL
Permit Number - T12CM00335
Review Name: RESUBMITTAL - TI ALL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/04/2012 | MARTIN BROWN | FIRE | REVIEW | Approved | |
| 04/04/2012 | ROBERT SHERRY | WATER | REVIEW | Approved | |
| 04/04/2012 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Approved | |
| 04/04/2012 | ERIC NEWCOMB | ZONING HC | REVIEW | Passed | |
| 04/05/2012 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Approved | |
| 04/05/2012 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | Kitchen design is now a part of this activity. [Original comment: The kitchen design (P1.05) is noted on sheet CS as being for "Reference Only", with a separate review and permit. If the kitchen is to be under a separate permit, clarify that intent on the drawing and identify how much of the plumbing work will be done in the area for the kitchen. Reference: Section 103.2.3, UPC 2006.] 1. Provide a direct waste connection for the wash and rinse sections of the 3-compartment sink, with an indirect connection for the sanitizing compartment only. Reference: Section 802.1, IPC 2006. |
| 04/06/2012 | STEVE SHIELDS | ZONING | REVIEW | Denied | PDSD TRANSMITTAL FROM: Steve Shields Lead Planner PROJECT: O'Rielly Chevrolet - New Used Car Sales Building & Remodel T12CM00333, T12CM00334, T12CM00335, Building Plan (2nd Review) TRANSMITTAL DATE: April 6, 2012 1. The building plan has been reviewed by Zoning Review Section but cannot approve the plan until all zoning comments or concerns have been addressed. 2. Zoning can not approve the building plan until the development package has been approved. 3. Zoning will re-review the building plan on the next submittal to insure compliance with the approved development package. Additional comments may be forthcoming. If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956 |
| 04/17/2012 | LOREN MAKUS | ENGINEERING | REVIEW | Denied | DP must be approved first. |
| 05/01/2012 | LEERAY HANLY | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
| 05/01/2012 | GERRY KOZIOL | WWM | REVIEW | Denied | NEED 5TH FLOOR CREDIT EVALUATION |