Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T12CM00334
Parcel: 128010230

Review Status: Completed

Review Details: COMMERCIAL - NEW

Permit Number - T12CM00334
Review Name: COMMERCIAL - NEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/04/2012 MARTIN BROWN FIRE REVIEW Approved
04/04/2012 ROBERT SHERRY WATER REVIEW Approved
04/04/2012 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Approved
04/04/2012 RONALD BROWN ADA REVIEW Passed
04/05/2012 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Denied 1. Comment not resolved; the detail on sheet P3.00 does not show how the platform is to be attached to the partition and no structural calculations have been supplied to show that the 357-pound load can be supported by the partition. [Original comment: Provide a design for the mounting shelf for the water heater along with structural calculations to show that the water heater is safely supported. Reference: Sections 310.0 and 314.5, UPC 2006.]
2. Coordinate the architectural and plumbing designs: sheet A3.00 shows 4" wide x 3" deep gutters with 2" x 3" downspouts but sheet P1.03 refers to 6" leaders and 6" scuppers. If gutters are to be used, see Table 1106.6, IPC 2006 for the required minimum gutter size and Table 1106.2, IPC 2006 for the minimum required downspout size. [Original comment: Revise the roof gutter and downspout sizing (shown on sheet A3.00) based on a storm of 60-minutes duration and a 100-year return period, i.e. 3" per hour. Use the entire roof area when doing the calculations. Reference: Sections 1106.1, 1106.3 and Table 11-3, UPC 2006.]
04/05/2012 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Denied When the condensate drains of two or more units are connected, the minimum size of the condensate drain shall be 1". [Original comment: Revise the size of the condensate drains in accordance with Section 307.2.1, IMC 2006, as amended by the City of Tucson.]
04/06/2012 STEVE SHIELDS ZONING REVIEW Denied PDSD TRANSMITTAL

FROM: Steve Shields
Lead Planner

PROJECT: O'Rielly Chevrolet - New Used Car Sales Building & Remodel
T12CM00333, T12CM00334, T12CM00335,
Building Plan (2nd Review)

TRANSMITTAL DATE: April 6, 2012

1. The building plan has been reviewed by Zoning Review Section but cannot approve the plan until all zoning comments or concerns have been addressed.

2. Zoning can not approve the building plan until the development package has been approved.

3. Zoning will re-review the building plan on the next submittal to insure compliance with the approved development package. Additional comments may be forthcoming.

If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956
04/17/2012 LOREN MAKUS ENGINEERING REVIEW Approved
05/01/2012 GERRY KOZIOL WWM REVIEW Denied NEED 5TH FLOOR CREDIT EVALUATION
05/01/2012 LEERAY HANLY ELECTRICAL-COMMERCIAL REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
05/22/2012 CPIERCE1 OUT TO CUSTOMER Completed