Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T12CM00333
Parcel: 128010230

Review Status: Completed

Review Details: COMMERCIAL - NEW

Permit Number - T12CM00333
Review Name: COMMERCIAL - NEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/09/2012 MARTIN BROWN FIRE REVIEW Denied Please show car wash building is within 300' of existing fire hydrant.
02/10/2012 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Denied 1. SHEET A1.04; BUILDING SECTION: THE CITY OF TUCSON REQUIRES ALL LETTERING (UPPER AND LOWER CASE) TO BE A MINIMUM OF 3/32" IN HEIGHT. REVISE.
2. SHEET S1.01; GENERAL STRUCTURAL NOTES: THE CITY OF TUCSON REQUIRES ALL LETTERING (UPPER AND LOWER CASE) TO BE A MINIMUM OF 3/32" IN HEIGHT. REVISE.
3. SHEET S1.01; DEFERRED SUBMITTALS: ALL DEFERRED SUBMITTALS MUST BE APPROVED IN WRITING BY RON BOOSE (BUILDING OFFICIAL) BEFORE THOSE SUBMITTALS WILL BE REVIEWED. RON.BOOSE@TUCSONAZ.GOV.
4. GENERAL: PROVIDE WRITTEN RESPONSES TO ALL REVIEW COMMENTS.
02/17/2012 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Denied 1. Specify how the non-potable water piping and outlets are to be identified. Reference: Section 601.2, UPC 2006.
2. If the materials for the process water piping systems downstream of the RPBP are not to be as specified for potable water on sheet P0.01, indicate what materials shall be used for each system (e.g. RO water, reclaimed water). Reference: Section 103.2.3, UPC 2006.
3. Provide a low-pressure cutoff and a pressure gauge for the booster pump as required per Section 609.8, UPC 2006.
4. Show how the 3" pumped-discharge of the sewage ejector connects to the 4" gravity drainage line. Reference: Section 710.4, UPC 2006.
5. Show that discharge of the sewage ejector will not result in the existing building drain becoming overloaded. Reference: Sections 101.5.1 and 710.5, UPC 2006.
6. Provide information to show that the specified control panel for the sewage ejector system meets the requirements of Section 710.9, UPC 2006 for the sequence of operation and alarms.
7. Provide a vent for the sewage ejector sump. Reference: Section 710.10, UPC 2006.
8. Provide specifications for the oil/sand interceptors and show that they comply with the requirements of Section 1016.2, UPC 2006.
9. Clarify the design of the venting for the oil/sand interceptors; why only one vent at the outlet when oil vapors can collect and be trapped in each compartment? Reference: Section 1016.3, UPC 2006.
02/17/2012 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Passed
02/17/2012 ROBERT SHERRY WATER REVIEW Approved
03/02/2012 LEERAY HANLY ELECTRICAL-COMMERCIAL REVIEW Denied 1. Plan sheet E1.07 . Plan seems to show more of a shell building minus obvious electrical eqipment usually associated with a carwash facility,such as pumps for detergents,waxes,coatings,vacumes, air compressers,lighting and associated wiring. Note on plan relates to carwash venders, dose this mean they will obtain a seperate permit complete with detailed plans?
03/06/2012 STEVE SHIELDS ZONING REVIEW Denied PDSD TRANSMITTAL

FROM: Steve Shields
Lead Planner

PROJECT: O'Rielly Chevrolet - New Used Car Sales Building & Remodel
T12CM00333, T12CM00334, T12CM00335,
Building Plan (1st Review)

TRANSMITTAL DATE: March 6, 2012

1. The building plan has been reviewed by Zoning Review Section but cannot approve the plan until all zoning comments or concerns have been addressed.

2. Zoning can not approve the building plan until the development package has been approved.

7. Zoning will re-review the building plan on the next submittal to insure compliance with the approved development package. Additional comments may be forthcoming.

If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956
03/06/2012 LOREN MAKUS ENGINEERING REVIEW Approved
03/13/2012 GERRY KOZIOL WWM REVIEW Denied NEED WW/WC/ TOM TOMCHAK REVIEW OF SAND/OIL INTERCEPTORS 724-6200 3035 W EL CAMINO DEL CERRO

Final Status

Task End Date Reviewer's Name Type of Review Description
03/13/2012 GERARDO BONILLA OUT TO CUSTOMER Completed