Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit Number: T12CM00290
Parcel: 115202610

Review Status: Completed

Review Details: RESUBMITTAL - TI ALL

Permit Number - T12CM00290
Review Name: RESUBMITTAL - TI ALL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
05/09/2012 ELIZABETH LEIBOLD ENGINEERING REVIEW Denied Building permits may not be issued until the layout and location of the buildings are approved on a stamped-approved Development Package D11-0032.
05/10/2012 MARTIN BROWN FIRE REVIEW Approved
05/15/2012 RONALD BROWN BUILDING-COMMERCIAL REVIEW Denied RESUBMITTAL COMMENTS:
1. As noted on comment 13, the non-compliance as per Comments 13 and 14 has to do with the lavatory encroaching upon the required water closet space, not the door swing. Please revise the toilet room for code compliance and resubmit.
2. As per comment 14, the community room exit doors are reloacted to comply with the exit separtion requirements as per section 1015.2, exception 2. On elevation 5/A2.3, the exit doors are not relocated.
3. As required by comment 24, structural details and calculations need to be provided for the two wall mounted water heaters. None have been submitted.
END OF REVIEW
05/24/2012 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Denied 1. The keynote on sheet A2.1 addresses only WH-4, which does not have the same support method as WH-5. Provide structural calculations for both instances. [Original comment: Provide a design for attaching the water heater shelves for WH4 and WH5 to the building structure, along with structural calculations to show that the water heaters are safely supported. Reference: Sections 106.3.1 and 301.2, IPC 2006.]
2. Comment not addressed. Provide a design for the proposed PEX water distribution manifold system. Reference: Section 604.3, IPC 2006.
3. Provide the dimensions for the scupper for the roof with a parapet and show how a rain water overflow capacity is being provided. [Original comment: Provide roof drainage calculations and dimensional information for the scupper, gutters and downspouts. Reference: Sections 1106 and 1107, IPC 2006.]
05/24/2012 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Denied Comment not resolved. A single residential range in the common kitchen will not require a Type I hood but the electrical power plans show two ranges being installed; clarify what is to be installed. [Original comment: Justify the lack of a Type I hood over the two ranges located in the common kitchen. Reference: Sections 106.3.1 and 507.2.3, IMC 2006.]
06/01/2012 TERRY STEVENS ZONING REVIEW Denied 02/10/2012

Development Services Department
Zoning Review Section

Terry Stevens
Lead Planner

Comments:

1. The building plan has been reviewed by Zoning Review Section but cannot approve the plan until it has been approved by the Engineering, and Landscape Review Sections and until all zoning comments or concerns have been addressed.

2. Zoning could not verify that the building plan was in compliance with the approved development plan. Please submit two copies of the approved and stamped development, landscape, and NPPO plans with the next building plan submittal.

3. Zoning will re-review the building plan on the next submittal to insure compliance with the approved site/development plan. Additional comments may be forthcoming.
06/11/2012 GERRY KOZIOL WWM REVIEW Denied - NEED WASTEWATER 3RD FLOOR REVIEW OF LOCATION/METHOD OF CONNECTION TO PUBLIC SEWER CHAD AMATEAU 740-6547
- NEED 1ST FLOOR MANHOLE CONSTRUCTION PERMIT APPROVAL - NEED DEQ REVIEW & APPROVAL TO CONSTRUCT ON SITE PRIVATE SEWER WITH MANHOLES DAVID AMASH 243-7400 33N STONE AV 7TH FLOOR BANK OF AMERICA BLDG - NEED COPY OF PRIVATE SEWER PLANS FOR BASE MAP UPDATE
- NEED PCRWRD/3RD FLOOR CAPACITY REVIEW - KURT STEMM 740-6534