| 01/20/2012 | MICHAEL ST. PAUL | ZONING | REVIEW | Denied | P&DS TRANSMITTAL FROM: Michael St.Paul, Planning Technician PROJECT: T12CM00140 1923 East 4th Street Bathroom and carport addition to SFR TRANSMITTAL: January 20, 2012 COMMENTS: the following comments are relative to an application for a Design Development Option (DDO). This Site requires a DDO for the setbacks to the east and west property lines. This site is in the R-1 Zone (LUC Section 2.3.4.2.A.1). The Development Designator is "G" (LUC Section 3.2.3.1.B) and the Perimeter Yard Indicator AA (LUC Section 3.2.6.4). The minimum setback to the east and west property lines is the greater of six feet or two-thirds the height of the structure's wall facing the property line. The wall height facing the west property line is thirteen (13) feet, six (6) inches. The minimum setback to the west property line is nine (9) feet. The wall height facing the east property line is ten (10) feet, six (6) inches. The minimum setback to the east property line is seven (7) feet. The proposed setback to both property lines is three (3) feet, six (6) inches. |
| 02/14/2013 | CPIERCE1 | BUILDING-RESIDENTIAL | REVIEW | Needs Review | |
| 02/14/2013 | CPIERCE1 | NPPO | REVIEW | Needs Review | |
| 02/14/2013 | CPIERCE1 | WWM | REVIEW | Needs Review | |
| 02/14/2013 | CPIERCE1 | ENGINEERING | REVIEW | Needs Review |