Permit Number: T12BU01170
Parcel: 101211300

Review Status: Completed

Review Details: GRADING

Permit Number - T12BU01170
Review Name: GRADING
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
10/16/2012 MICHAEL ST. PAUL ZONING REVIEW Denied October 24, 2012

Development Services Department
Zoning Review Section

Michael St.Paul
Planning Technician

T12BU01170 Grading Plans for T12CM0000?
5161 North Gracious Court


Comments:

1. The grading plan has been reviewed by Zoning Review Section but cannot approve the plan without an approved plot plan for Lot 6.

2. The grading plan appears to match the approved subdivision plat. Provide lot dimension an bearing along the north property line, and correct confirm dimensions with the final plat.

3. Zoning will re-review the grading plan on the next submittal to ensure compliance with the approved site plan. Additional comments may be forthcoming.
10/22/2012 ELIZABETH LEIBOLD ENGINEERING REVIEW Approved DATE: October 22, 2012
TO: Peter Livingston, P.E.
SUBJECT: 5161 N Gracious Ct Grading Plan Review
LOCATION: Gracious Estates lot 6
REVIEWER: Elizabeth Leibold P.E.
ACTIVITY NUMBER: T12BU01170

Summary: Engineering Division has reviewed the submitted plan review package including a copy of the grading plan. Engineering recommends approval of the grading permit. See below for permit conditions to be completed / addressed during grading construction. Also note for future grading plans, please assure grading limits include stormwater control area.

GRADING PERMIT CONDITIONS:
1) The following conditions apply to grading permit T12BU01170 for lot 6:
a) Any rip rapped slopes shall have handplaced stone with filter fabric per HDZ requirements, unless required to have handplaced grouted rip rap or other slope protection as per geotechnical engineering report or addenda.
b) There shall be no disturbance, and that materials and / or construction equipment may not be stockpiled or parked, outside of approved disturbance limits at any time.
c) All grading construction work shall conform to IBC Chapter 18, City of Tucson DS Sec.11-01, and Hillside Development Zone requirements.
d) Any future wall openings shall be provided for surface drainage from yard or patio areas.
e) If grading construction is expected to last longer than the expiration date of the grading permit, contact City of Tucson Planning & Development Services Department to renew/extend the Grading Permit. If Final Grading Inspection has not been completed before the Grading Permit expires, and the permit has not been renewed, additional fees and reviews may be required.
f) Call for PDSD Engineering Pre-construction meeting and other Inspections. For a PDSD Engineering Inspection, call IVR (740-6970), or schedule with a Customer Service Representative at the Planning & Development Services Department, or contact PDSD Engineering at 837-4888, or schedule inspections online at: http://www.ci.tucson.az.us/dsd/Online_Services/Online_Permits/online_permits.html
g) Any revision to the Grading Plan may require a re-submittal of a revised grading plan for review. Contact PDSD Engineering at 791-5550 to discuss changes in grading design.
h) If grading construction is expected to last longer than the expiration date of the grading permit, contact PDSD to renew/extend the Grading Permit. If Final Grading Inspection has not been completed before the Grading Permit expires, and the permit has not been renewed, additional fees and reviews may be required.
i) The permitee shall notify the PDSD when the grading operation is ready for final grading inspection. Final grading approval shall not be given until all work, including installation of all erosion control measures have been completed in accordance with the approved grading plan and grading permit.

I can be reached at 837-4934 if you have questions.

Elizabeth Leibold, P.E., CPM, CFM
Civil Engineer
Engineering Division
Planning & Development Services Department
10/31/2012 CPIERCE1 NPPO REVIEW Needs Review

Final Status

Task End Date Reviewer's Name Type of Review Description
10/31/2012 CPIERCE1 OUT TO CUSTOMER Completed