Permit Review Detail
Review Status: Completed
Review Details: BILLBOARD - BLDG30days
Permit Number - T12BU01060
Review Name: BILLBOARD - BLDG30days
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
09/11/2012 | LEERAY HANLY | BUILDING-COMMERCIAL | REVIEW | Needs Review | |
10/01/2012 | GLENN MOYER | ADMINISTRATIVE | ADMIN REVIEW | Denied | BRC Comments Below are comments for the required modification submittal for COT ID# 214 at 6501 South Nogales Highway (T12BU01060). Sheet 1 of 2 1. In General Notes #9, delete "(Y)" (there is no "Y" in Exhibit 9, Section 2). 2. In General Notes #9, add "(B)" and "(F)" (for respective replacement of stringers (apron) and angle clips as shown on Sheet 2). 3. Depict and identify the path of the relocated underground electrical service on the aerial photograph underlay. Sheet 2 of 2 1. In the boxed note on Exhibit 9, Section 2, delete "(Y)" (there is no "Y" in Exhibit 9, Section 2). 2. In the boxed note on Exhibit 9, Section 2, add "(B)" and "(F)" (for respective replacement of stringers (apron) and angle clips as shown on Sheet 2). 3. Provide detail on the existing and any replacement for underground electrical feed, including conduit material/size and trench dimensions. 4. The boxed note on Exhibit 9 includes Section 2(x), but the Scope of Work does not list any electrical replacement work; clarify whether any electrical parts are to be replaced. 5. Include all electrical removal and reinstallation/replacement work in Scope of Work; clarify whether all electrical parts (other than the underground feed) are to be relocated in their current configuration. 6. Provide standard electrical plan details, including light fixture mounting, description of existing lamps, panel schedule, riser diagram, and one-line diagram. 7. Add note that beam holes to be backfilled only with native earth removed from holes. 8. The original engineered plan shows beam depth of 6'0"; use this as the default beam depth (subject to field measurement upon excavation; the depiction shows the beam depth as almost 8'0"). 9. The plan specifies replacement of TEK screws, but it appears that there are no existing TEK screws; delete the reference to TEK screws or be more specific about the number and location of such existing and replacement screws. |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
10/04/2012 | FERNE RODRIGUEZ | OUT TO CUSTOMER | Completed |