Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit Number: T12BU00909
Parcel: 135084630

Address:
1345 S KOLB RD

Review Status: Completed

Review Details: WALLS - SUBMITTAL

Permit Number - T12BU00909
Review Name: WALLS - SUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/22/2012 LOREN MAKUS ENGINEERING REVIEW Denied Revise the drainage statement floodplain delineation. The aerial photos of the site show a curb island and solid waste container enclosure upstream of cross-section 4. Revise the analysis to include a cross section at these obstruction and upstream of them as well. (SMDDFM Fig. 5.1)

Provide details of the fence design to demonstrate that the clear openings in the area affected by the regulatory flows. Show how the gates will respond to potential clogging by debris carried downstream from the subdivision areas. Discuss the use of break-away latches or some other means for preventing adverse effects caused by clogging.
08/23/2012 STEVE SHIELDS ZONING REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
09/05/2012 CPIERCE1 OUT TO CUSTOMER Completed