Permit Number: T12BU00589
Parcel: 14011021F

Address:
2502 E BENSON HY

Review Status: Completed

Review Details: BILLBOARD - BLDG30days

Permit Number - T12BU00589
Review Name: BILLBOARD - BLDG30days
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
05/09/2012 LEERAY HANLY BUILDING-COMMERCIAL REVIEW Needs Review
06/05/2012 GLENN MOYER ADMINISTRATIVE ADMIN REVIEW Denied BRC Comments

Below are comments for the modification and repair submittal for COT ID# 8
at 2502 East Benson Highway (T12BU0589).

Sheet 1 of 1

1. In Billboard Notes, add APN# 140-11-021E or otherwise explain why
omitted.

2. Correct legal description to provide separately for both APN#
140-11-021E and 140-11-021F.

3. Show graphically and by legal description any easements of record that
pertain to the billboard use, including access and visibility.

Sheet 2 of 2

1. Specify the point of disconnect between the upper structure to be
removed and the lower structure; in particular specify whether the unipole
extension is to be temporarily removed with the upper structure or not.

2. Add note that the upper structure to be temporarily removed is to remain
on site and specify its location (e.g. on ground, trailer, or other location
and approximate location on site).

3. Specify the junction box or other upper point of disconnect for the
riser conduit/wiring to be shortened.

4. South Face Elevation appears to be for north face (given crossover/end
rail location); change to north face or otherwise address and specify other
differences between south and north elevations (rather than only indicating
similar).

5. In Scope of Work, clarify the location of the 24 A-325 bolts to be
replaced (i.e., how many and which flanges are being mated).

6. Add note that the orientation of upper structure to remain the same and
not to be rotated and that base and temporarily removed section of unipole
to be marked to match orientation when welded.

7. Detail the finished clearance between the upper structure and the roof
of the adjacent building.

8. Specify the number and locations of existing TEK Screws (the existing
installation appears to use few, if any).

Final Status

Task End Date Reviewer's Name Type of Review Description
07/10/2012 FERNE RODRIGUEZ OUT TO CUSTOMER Completed