Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - OVERLAY ZONE REVIEW
Permit Number - T11SA00336
Review Name: RESUBMITTAL - OVERLAY ZONE REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/16/2012 | JASON GREEN | ENGINEERING | REVIEW | Denied | DATE: February 16, 2012 SUBJECT: Bella Vista Apartment HDZ & SCZ Overlay- 3rd Engineering Review TO: Patricia Gehlen, CDRC Manager LOCATION: 1900 W Speedway Blvd, T15S R13E Sec3/10 Ward 1 REVIEWERS: Jason Green, CFM ACTIVITY: T11SA00336 SUMMARY: Engineering Division of Planning & Development Services Department has received and reviewed the proposed overlay package. Engineering Division does not recommend approval of the overlay package at this time. The following items need to be addressed: HDZ OVERLAY COMMENTS: 1) DS Sec.9-01.2.3: The following information is to be provided on the overlay sheets for all projects affected by the Hillside Development Zone review: a) Completed. b) Restated: Topographic information of the existing terrain, prior to any grading, grubbing, clearing, excavation, or modification, with contour intervals as specified in Development Standard 9-01.0. The overlay package should include a separate sheet that shows all topographical information of the property and it should not include any of the proposed improvements per the referenced standard. Do not show the buildings, PAAL, sidewalk, refuse container, etc. Per the response letter from hilgartwilson it states a new sheet has been added to show this information, however the submittal did not included this sheet. c) Completed. d) Restated: The following slope analysis information must be provided on the plan. For specific information on calculations of slope, refer to Development Standard 9-01.0. I. Completed. II. Restated: If the development criteria of Sec. 2.8.1.6 of the LUC require an analysis of sloped areas, those areas of fifteen (15) percent or greater slope must be shown on a topographic map. The overlay package should include a separate sheet that shows all topographical information of the property and it should not include any of the proposed improvements per the referenced standard. 2) Restated: DS Sec.9-01.4.1: The Average Natural Cross Slope (ACS) of a site is determined in the following manner. The site is depicted on a topographic map of the existing terrain, prior to any grading, grubbing, clearing, excavation, or modification, utilizing a scale no smaller than one (1) inch equals one hundred (100) feet, with the following contour interval. The HDZ Sheet that shows the ACS should not contain the proposed improvements in order to calculate the slope analysis and show areas of 15% or greater. Per the response letter from hilgartwilson it states a new sheet has been added to show this information, however the submittal did not included this sheet. 3) Completed. SCENIC CORRIDOR OVERLAY COMMENTS: 4) Completed. 5) Completed. GENERAL COMMENTS: A meeting is requested to discuss this project with the Engineering Division and the consultant to help expedite the resubmittal prior to resubmitting the plans due to the HDZ comments that have being restated for the 3rd time. I can be reached at 837-4929 to schedule a meeting. Jason Green, CFM Senior Engineer Associate Engineering Division Planning & Development Services Department |
| 02/22/2012 | PATRICIA GEHLEN | ZONING-DECISION LETTER | WRITE DECISION LETTER | Denied | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES February 22, 2012 Philip Carhuff, AIA Krebs Carhuff Architects 3149 East Prince Road #151 Tucson, Arizona 85716 Subject: T11SA00336 Hillside Development and Scenic Corridor Overlay Zones for 1900 West Speedway Blvd (D11-0026) Dear Phil: Your submittal of February 14, 2012 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter for each agency explaining how each outstanding requirement has been addressed: ALL BLUELINES MUST BE FOLDED 2 Copies Revised Overlay Zone submittal package as detailed in the on line comments (Engineering, DSD). Should you have any questions, please call me at 837-4919. Sincerely, Patricia Y. Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: (520) 577-4599 |