Plan Number: T11PI00006
Parcel: Unknown

Address:
2802 N 1ST AV

Review Status: Completed

Review Details: PIA - RESUBMITTAL

Plan Number - T11PI00006
Review Name: PIA - RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/22/2011 RICHARD LEIGH DOT ENGINEERING REVIEW Denied August 19, 2011


SUBJECT: QUIKTRIP, 1ST AVENUE AND GLENN STREET I-2011-007 T11PI00006, 2nd Rev.

PROJECT REVIEWER: Richard Leigh, DOT, Permits and Codes Section

Permits and Codes Section has reviewed the PIA Plan and does not recommend approval of the PIA Plan at this time. The following comments need to be addressed in the next submittal.

1. Clearly indicate the type of curb proposed for the curb returns at the driveway entrances and the proposed median island at the Glenn Ave entrance.

2. Sheet 2, Detail 1& 3: A minimum 2' set back per City of Tucson Development Standard 11-09.0 is required from the hinge point of any cut and fill slope and the property line. FYI, the setback from the property line and hinge point shown on the development plan and that shown on the PIA paving plans conflict.

3. Provide a sidewalk scupper at the curb opening located at Sta. +/- 12+34 LF (Glenn Street) to convey the 10 Yr flood discharge underneath the sidewalk per D.S. 3-01.4.4.F.

4. Sheet 4, Detail A11: Label detail as not being part of the PIA.

Refer to redline plans for additional comments and comment details.

If you have any questions, I can be reached at 837-6647 or Richard.Leigh@tucsonaz.gov
08/22/2011 RLEIGH1 UTILITY CLEARANCES COT STREETS DIVISION Completed
08/22/2011 RLEIGH1 UTILITY CLEARANCES COT WATER NEW DEVELOPMENT Completed
08/22/2011 RLEIGH1 UTILITY CLEARANCES PC WASTEWATER MGMT Completed
08/22/2011 RLEIGH1 UTILITY CLEARANCES QUEST COMMUNICATION Completed
08/22/2011 RLEIGH1 UTILITY CLEARANCES TUCSON ELECTRIC POWER CO Completed
08/22/2011 RLEIGH1 UTILITY CLEARANCES COX COMMUNICATION Completed
08/22/2011 RLEIGH1 UTILITY CLEARANCES SOUTHWEST GAS CORP Completed
08/22/2011 RLEIGH1 UTILITY CLEARANCES EL PASO NATURAL GAS Completed
08/22/2011 RLEIGH1 UTILITY CLEARANCES KINDER MORGAN ENERGY Completed
08/23/2011 JOSE ORTIZ DOT TRAFFIC REVIEW Approved
08/24/2011 RICHARD LEIGH PIA COORDINATOR CUSTOMER CALLED; PLANS @ AMBASSADOR Completed
08/24/2011 RICHARD LEIGH PIA COORDINATOR OUT TO CUSTOMER Completed