Plan Number - T11PI00005
Review Name: PIA - SUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/23/2011 GARY WITTWER DOT LANDSCAPE REVIEW Approv-Cond Nice plan.
This falls under the original maintenance agreement- correct?
Note 23 is in question?
It appears that you are providing the required easements for sleeves and future lines. Please confirm.
03/30/2011 LANCE PETERSON DOT STREET MAINTENANCE REVIEW Denied Provide Drainage structures maintenance access.
04/04/2011 RLEIGH1 UTILITY CLEARANCES COT STREETS DIVISION Denied
04/04/2011 RICHARD LEIGH DOT ENGINEERING REVIEW Denied March 31, 2011


SUBJECT: NOBEL WAY, PAVING IMPROVEMENT PLANS, I-2011-006, T11PI00005, 1st Rev.

PROJECT REVIEWER: Richard Leigh, DOT, Permits and Codes Section

Permits and Codes Section has reviewed the PIA Plan and does not recommend approval of the PIA Plan at this time. The following comments need to be addressed in the next submittal.

1. Include the plan number "I-2010-006" in title block of each sheet.

2. Include Development Services Department PIA activity number "T11PI0005" on cover sheet.

3. Revise legend on cover sheet to reflect the symbols and lines used in drawing.

4. Indicate the composition and placement requirements for the proposed "2' high protective berm" along the west side of the proposed roadway for construction and inspection purposes.

5. Have pedestrian access easements been dedicated for where the sidewalk meanders onto private property?

6. Have drainage and/or flowage easements and maintenance access easements been dedicated for drainage structures extending beyond the public rights-of-way?

7. Provide construction details for the proposed junction structure and manhole at Sta. 14+65 Nobel Way.

8. Provide construction details for the proposed storm drain inlet at Sta. 14+65 Nobel Way.

Refer to redline plans for additional comments and comment details.

If you have any questions, I can be reached at 837-6647 or Richard.Leigh@tucsonaz.gov
04/04/2011 RLEIGH1 UTILITY CLEARANCES COT WATER NEW DEVELOPMENT Denied
04/04/2011 RLEIGH1 UTILITY CLEARANCES PC WASTEWATER MGMT Denied
04/04/2011 RLEIGH1 UTILITY CLEARANCES QUEST COMMUNICATION Denied
04/04/2011 RLEIGH1 UTILITY CLEARANCES TUCSON ELECTRIC POWER CO Denied
04/04/2011 RLEIGH1 UTILITY CLEARANCES COX COMMUNICATION Denied
04/04/2011 RLEIGH1 UTILITY CLEARANCES SOUTHWEST GAS CORP Denied
04/04/2011 RLEIGH1 UTILITY CLEARANCES EL PASO NATURAL GAS Denied
04/04/2011 RLEIGH1 UTILITY CLEARANCES KINDER MORGAN ENERGY Denied
04/05/2011 JOSE ORTIZ DOT TRAFFIC REVIEW Denied April 5, 2011
ACTIVITY NUMBER: T11PI0005
PROJECT NAME: Nobel Way
PROJECT ADDRESS: 1550 E 36th St
PROJECT REVIEWER: Jose E. Ortiz PE, Traffic Engineer

Resubmittal Required: Traffic Engineering does not recommend approval of the PIA Plan; therefore a revised PIA Plan is required for re-submittal. The following items must be revised or added to the plan. Include a response letter with the next submittal that states how all comments have been addressed.

1. Address the redlines on the submitted drawings. During the next submittal please re-submit the roll of redlines for back checking purposes.

2. Meetings with appropriate TDOT staff can be arranged to discuss and/or to clarify the Traffic Engineering redlines.


If you have any questions, I can be reached at 791-4259 x76730 or Jose.Ortiz@tucsonaz.gov
04/06/2011 RICHARD LEIGH PIA COORDINATOR CUSTOMER CALLED; PLANS @ AMBASSSADOR Completed Please submit Utility Receipts from the following utility companies:

City of Tucson
Transportation Department,
Streets Division

Tucson Water:

Pima County
Wastewater Management

Qwest Communications

Tucson Electric Power

Cox Communications

Southwest Gas Corp.

El Paso Natural Gas*

Kinder Morgan Energy*

* When the above two utilities are not involved, a form filled out with the "RECEIVED BY:" line stating "not needed" may be submitted.


If you have any questions, I can be reached at 837-6647 or Richard.Leigh@tucsonaz.gov
04/06/2011 RICHARD LEIGH PIA COORDINATOR OUT TO CUSTOMER Completed Please submit Utility Receipts from the following utility companies:

City of Tucson
Transportation Department,
Streets Division

Tucson Water:

Pima County
Wastewater Management

Qwest Communications

Tucson Electric Power

Cox Communications

Southwest Gas Corp.

El Paso Natural Gas*

Kinder Morgan Energy*

* When the above two utilities are not involved, a form filled out with the "RECEIVED BY:" line stating "not needed" may be submitted.


If you have any questions, I can be reached at 837-6647 or Richard.Leigh@tucsonaz.gov