Plan Review Detail
Review Status: Completed
Review Details: PIA - SUBMITTAL
Plan Number - T11PI00005
Review Name: PIA - SUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/23/2011 | GARY WITTWER | DOT LANDSCAPE | REVIEW | Approv-Cond | Nice plan. This falls under the original maintenance agreement- correct? Note 23 is in question? It appears that you are providing the required easements for sleeves and future lines. Please confirm. |
| 03/30/2011 | LANCE PETERSON | DOT STREET MAINTENANCE | REVIEW | Denied | Provide Drainage structures maintenance access. |
| 04/04/2011 | RLEIGH1 | UTILITY CLEARANCES | COT STREETS DIVISION | Denied | |
| 04/04/2011 | RICHARD LEIGH | DOT ENGINEERING | REVIEW | Denied | March 31, 2011 SUBJECT: NOBEL WAY, PAVING IMPROVEMENT PLANS, I-2011-006, T11PI00005, 1st Rev. PROJECT REVIEWER: Richard Leigh, DOT, Permits and Codes Section Permits and Codes Section has reviewed the PIA Plan and does not recommend approval of the PIA Plan at this time. The following comments need to be addressed in the next submittal. 1. Include the plan number "I-2010-006" in title block of each sheet. 2. Include Development Services Department PIA activity number "T11PI0005" on cover sheet. 3. Revise legend on cover sheet to reflect the symbols and lines used in drawing. 4. Indicate the composition and placement requirements for the proposed "2' high protective berm" along the west side of the proposed roadway for construction and inspection purposes. 5. Have pedestrian access easements been dedicated for where the sidewalk meanders onto private property? 6. Have drainage and/or flowage easements and maintenance access easements been dedicated for drainage structures extending beyond the public rights-of-way? 7. Provide construction details for the proposed junction structure and manhole at Sta. 14+65 Nobel Way. 8. Provide construction details for the proposed storm drain inlet at Sta. 14+65 Nobel Way. Refer to redline plans for additional comments and comment details. If you have any questions, I can be reached at 837-6647 or Richard.Leigh@tucsonaz.gov |
| 04/04/2011 | RLEIGH1 | UTILITY CLEARANCES | COT WATER NEW DEVELOPMENT | Denied | |
| 04/04/2011 | RLEIGH1 | UTILITY CLEARANCES | PC WASTEWATER MGMT | Denied | |
| 04/04/2011 | RLEIGH1 | UTILITY CLEARANCES | QUEST COMMUNICATION | Denied | |
| 04/04/2011 | RLEIGH1 | UTILITY CLEARANCES | TUCSON ELECTRIC POWER CO | Denied | |
| 04/04/2011 | RLEIGH1 | UTILITY CLEARANCES | COX COMMUNICATION | Denied | |
| 04/04/2011 | RLEIGH1 | UTILITY CLEARANCES | SOUTHWEST GAS CORP | Denied | |
| 04/04/2011 | RLEIGH1 | UTILITY CLEARANCES | EL PASO NATURAL GAS | Denied | |
| 04/04/2011 | RLEIGH1 | UTILITY CLEARANCES | KINDER MORGAN ENERGY | Denied | |
| 04/05/2011 | JOSE ORTIZ | DOT TRAFFIC | REVIEW | Denied | April 5, 2011 ACTIVITY NUMBER: T11PI0005 PROJECT NAME: Nobel Way PROJECT ADDRESS: 1550 E 36th St PROJECT REVIEWER: Jose E. Ortiz PE, Traffic Engineer Resubmittal Required: Traffic Engineering does not recommend approval of the PIA Plan; therefore a revised PIA Plan is required for re-submittal. The following items must be revised or added to the plan. Include a response letter with the next submittal that states how all comments have been addressed. 1. Address the redlines on the submitted drawings. During the next submittal please re-submit the roll of redlines for back checking purposes. 2. Meetings with appropriate TDOT staff can be arranged to discuss and/or to clarify the Traffic Engineering redlines. If you have any questions, I can be reached at 791-4259 x76730 or Jose.Ortiz@tucsonaz.gov |
| 04/06/2011 | RICHARD LEIGH | PIA COORDINATOR | CUSTOMER CALLED; PLANS @ AMBASSSADOR | Completed | Please submit Utility Receipts from the following utility companies: City of Tucson Transportation Department, Streets Division Tucson Water: Pima County Wastewater Management Qwest Communications Tucson Electric Power Cox Communications Southwest Gas Corp. El Paso Natural Gas* Kinder Morgan Energy* * When the above two utilities are not involved, a form filled out with the "RECEIVED BY:" line stating "not needed" may be submitted. If you have any questions, I can be reached at 837-6647 or Richard.Leigh@tucsonaz.gov |
| 04/06/2011 | RICHARD LEIGH | PIA COORDINATOR | OUT TO CUSTOMER | Completed | Please submit Utility Receipts from the following utility companies: City of Tucson Transportation Department, Streets Division Tucson Water: Pima County Wastewater Management Qwest Communications Tucson Electric Power Cox Communications Southwest Gas Corp. El Paso Natural Gas* Kinder Morgan Energy* * When the above two utilities are not involved, a form filled out with the "RECEIVED BY:" line stating "not needed" may be submitted. If you have any questions, I can be reached at 837-6647 or Richard.Leigh@tucsonaz.gov |